A Novel Portable Seizure Detection Alarm System: Preliminary Results
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The unpredictable and random occurrence of seizures is of the most distressful issue affecting patients and their families. Unattended seizures can have serious consequences including injury or death. The objective of this study is to develop a small, portable, wearable device capable of detecting seizures and alerting patients and families on recognition of specific seizures' motor activity. Ictal data were prospectively obtained in consecutive patients admitted to two video-EEG units. This study included patients with a history of motor seizures, clonic or tonic, or tonic-clonic seizures or patients with complex partial seizures with frequent secondary generalization. A "Motion Sensor" unit mounted on a bracelet was attached to one wrist. The "Sensor" contains a three-axis accelerometer and a transmitter. The three-axis movements' data were transmitted to a portable computer. Algorithm specially developed for this purpose analyzed the recorded data. Seizures' alerts were compared with the video-EEG data. Ictal data were acquired in 15 of the 31 recruited patients. The algorithm correctly identified 20 of 22 (91%) captured seizures and generated an alarm within a median period of 17 seconds. All events lasting >30 seconds (i.e., 19 events) were identified. The system failed to identify 2 of 22 seizures (9%). There were eight false alarms during 1,692 hours of monitoring. Preliminary data suggest that this motion detection device/alarm system can identify most motor seizures with high sensitivity and with a low false alarm rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nijsen, T. M. E., Arends, J. B. A. M., Griep, P. A. M., & Cluitmans, P. J. M. (2005) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2005.04.011 · Cited by 139
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Seizure detection, seizure prediction, and closed-loop warning systems in epilepsy
Ramgopal, S., Thome-Souza, S., Jackson, M., Kadish, N. E., Sánchez Fernández, I., Klehm, J., Bosl, W., Reinsberger, C., Schachter, S., & Loddenkemper, T. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.023 · Cited by 469
“204 false positives Kramer, 2011 [40] Single 3-D accelerometer worn on the wrist/tonic, GTCS Time domain- and frequency domain-based algorithm Identified 91% of clonic or tonic, tonic–clonic, or secondarily generalized seizures Van de Vel, 2012 [41] One 3-D accelerometer on each limb/hypermotor seizures Movement detec…”
BackgroundSeizure diaries for clinical research and practice: Limitations and future prospects
Fisher, R. S., Blum, D. E., DiVentura, B., Vannest, J., Hixson, J. D., Moss, R., Herman, S. T., Fureman, B. E., & French, J. A. (2012) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2012.04.128 · Cited by 304
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233
Beniczky, S., Polster, T., Kjaer, T. W., & Hjalgrim, H. (2013) · Epilepsia · doi:10.1111/epi.12120 · Cited by 230
Metadata
- Authors
- Kramer, U., Kipervasser, S., Shlitner, A., & Kuzniecky, R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2011-02
- Volume
- 28
- Issue
- 1
- Pages
- 36-38
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W1968372332
- Cited by
- 122
- References
- 1
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Portable Seizure Detection Alarm System: Preliminary Results. https://app.cochat.ai/papers/10.1097/wnp.0b013e3182051320
- The paper
- Kramer, U., Kipervasser, S., Shlitner, A., & Kuzniecky, R. (2011). A Novel Portable Seizure Detection Alarm System: Preliminary Results. Journal of Clinical Neurophysiology. https://doi.org/10.1097/wnp.0b013e3182051320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.