CoChat

Two Versus One High-Frequency Repetitive Transcranial Magnetic Stimulation Session per Day for Treatment-Resistant Depression: A Randomized Sham-Controlled Trial

Open access
Theleritis, Christos, Sakkas, Pavlos, Paparrigopoulos, Thomas, Vitoratou, Silia, Tzavara, Chara, Bonaccorso, Stefania, Politis, Antonios, Soldatos, Constantin R., Psarros, Costantin · 2017 · The Journal of ECT
Cited by 48

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Objectives: High-frequency repetitive transcranial magnetic stimulation (HF-rTMS) has proven antidepressant effects, but the optimal frequency of sessions remains unclear. Methods: We conducted a 3-week, sham-controlled trial to assess the antidepressant efficacy of 1 active HF-rTMS session per day (A1 group) compared with 2 per day (A2 group) and equivalent sham sessions (once a day, S1 group; twice a day, S2 group) in patients with treatment-resistant major depression with a subsequent 2-week follow-up period. One hundred seventy-seven patients were screened, of whom 105 met eligibility criteria and 98 consented and were randomized. The HF-rTMS (20 Hz) was targeted to the left prefrontal cortex in sessions of approximately 40 trains (2 seconds each) at 100% resting motor threshold with an intertrain interval of 1 minute. Treatment response was defined as a 50% or greater decrease in the Hamilton Depression Rating Scale (HDRS) score and/or Clinician Global Impressions-Severity of Illness (CGI-S) score of 3 or less. Remission was defined as HDRS score less than 8 and/or CGI-S score of 2 or less. Results: Practically none of the subjects in either sham groups achieved remission. Increased odds of remission were present for CGI-S by stimulating twice rather than once per day (odds ratio [OR] = 1.5, P = 0.018), whereas there was a marginal result for HDRS (OR = 3.9, P = 0.066). Patients who had lower baseline HDRS (OR = 0.75, P = 0.014) and CGI-S scores (OR = 0.18, P = 0.001) were more likely to achieve remission. Conclusions: Twice per day active HF-rTMS might be more effective than once per day active HF-rTMS or sham stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/yct.0000000000000387

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 48

Metadata

Authors
Theleritis, C., Sakkas, P., Paparrigopoulos, T., Vitoratou, S., Tzavara, C., Bonaccorso, S., Politis, A., Soldatos, C. R., & Psarros, C.
Venue
The Journal of ECT
Published
2017-09
Volume
33
Issue
3
Pages
190-197
ISSN
  • 1095-0680 (ISSN-L)
  • 1533-4112
OpenAlex
W2568829328
Cited by
48
References
13
FWCI
1.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two Versus One High-Frequency Repetitive Transcranial Magnetic Stimulation Session per Day for Treatment-Resistant Depression: A Randomized Sham-Controlled Trial. https://app.cochat.ai/papers/10.1097/yct.0000000000000387
The paper
Theleritis, C., Sakkas, P., Paparrigopoulos, T., Vitoratou, S., Tzavara, C., Bonaccorso, S., Politis, A., Soldatos, C. R., & Psarros, C. (2017). Two Versus One High-Frequency Repetitive Transcranial Magnetic Stimulation Session per Day for Treatment-Resistant Depression: A Randomized Sham-Controlled Trial. The Journal of ECT. https://doi.org/10.1097/yct.0000000000000387

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.