Modelling the mechanics of partially mineralized collagen fibrils, fibres and tissue
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Progressive stiffening of collagen tissue by bioapatite mineral is important physiologically, but the details of this stiffening are uncertain. Unresolved questions about the details of the accommodation of bioapatite within and upon collagen's hierarchical structure have posed a central hurdle, but recent microscopy data resolve several major questions. These data suggest how collagen accommodates bioapatite at the lowest relevant hierarchical level (collagen fibrils), and suggest several possibilities for the progressive accommodation of bioapatite at higher hierarchical length scales (fibres and tissue). We developed approximations for the stiffening of collagen across spatial hierarchies based upon these data, and connected models across hierarchies levels to estimate mineralization-dependent tissue-level mechanics. In the five possible sequences of mineralization studied, percolation of the bioapatite phase proved to be an important determinant of the degree of stiffening by bioapatite. The models were applied to study one important instance of partially mineralized tissue, which occurs at the attachment of tendon to bone. All sequences of mineralization considered reproduced experimental observations of a region of tissue between tendon and bone that is more compliant than either tendon or bone, but the size and nature of this region depended strongly upon the sequence of mineralization. These models and observations have implications for engineered tissue scaffolds at the attachment of tendon to bone, bone development and graded biomimetic attachment of dissimilar hierarchical materials in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fantner, G. E., Hassenkam, T., Kindt, J. H., Weaver, J. C., Birkedal, H., Pechenik, L., Cutroni, J. A., Cidade, G. A. G., Stucky, G. D., Morse, D. E., et al. (2005) · Nature Materials · doi:10.1038/nmat1428 · Cited by 933 · cited 3×
“20) containing a relatively small amount of non-collagenous proteins that serve to bind adjacent collagen fibrils [31].”
BackgroundMicrofibrillar structure of type I collagen in situ
Orgel, J. P. R. O., Irving, T. C., Miller, A., & Wess, T. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502718103 · Cited by 930
Cited by
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Self-citationDiameterJ: A validated open source nanofiber diameter measurement tool
Hotaling, N. A., Bharti, K., Kriel, H., & Simon, C. G. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.05.015 · Cited by 531
The microstructure and micromechanics of the tendon–bone insertion
Rossetti, L., Kuntz, L. A., Kunold, E., Schock, J., Müller, K. W., Grabmayr, H., Stolberg-Stolberg, J., Pfeiffer, F., Sieber, S. A., Burgkart, R., et al. (2017) · Nature Materials · doi:10.1038/nmat4863 · Cited by 401
Fibroblasts slow conduction velocity in a reconstituted tissue model of fibrotic cardiomyopathy
Spencer, T. M., Blumenstein, R. F., Pryse, K. M., Lee, S.-L., Glaubke, D. A., Carlson, B. E., Elson, E. L., & Genin, G. M. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00576 · Cited by 23
Self-citationShi, Q., Chen, Y., Li, M., Zhang, T., Ding, S., Xu, Y., Hu, J., Chen, C., & Lu, H. (2020) · Annals of Translational Medicine · doi:10.21037/atm-20-3661 · Cited by 16
“Since the modulus ranges drastically across BTI (47,48) to match the moduli of the stiff, ideal decellularized protocol should preserve the graded mineral distribution of NET.”
Self-citation
Metadata
- Authors
- Liu, Y., Thomopoulos, S., Chen, C., Birman, V., Buehler, M. J., & Genin, G. M.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2014-03-06
- Volume
- 11
- Issue
- 92
- Pages
- 20130835
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2144713899
- Cited by
- 99
- References
- 2
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.