The DOI matches its Crossref record.
The tension of metallic films deposited by electrolysis
Open accessAbstract
It is well known that metallic films deposited electrolytically are in many cases liable to peel off if deposited to any considerable thickness. This is the case with nickel which, when deposited over a certain thickness, will curl up into beautiful close rolls, especially if it does not adhere very tightly to the body on which it is deposited. For example, if a piece of glass is silvered by any of the usual silvering solutions, and then nickel is deposited on the silver, it is found that the nickel and silver peel off the glass in close tight rolls almost at once. In ‘Practical Electro-Chemistry,' by Bertram Blount, reference is made on pp. 114 and 272 to the tendency of nickel to peel off, and it is stated that it “will peel—spontaneously and without assignable cause” (p. 272), but that a thick coating can be obtained by keeping the solution at between 50° and 90°C. The late Earl of Rosse tried, about 1865, to make flat mirrors by coating glass with silver chemically, and then electroplating with copper; but he found that, owing to the “contraction” of the copper film, it became detached from the glass. I have had the' same experience in protecting silver 61ms in searchlight reflectors by a film of electro-deposited copper, it being found that if the film of copper is more than 0.01 mm. thick peeling is apt to take place.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Janssen, G. C. A. M., Abdalla, M. M., van Keulen, F., Pujada, B. R., & van Venrooy, B. (2009) · Thin Solid Films · doi:10.1016/j.tsf.2008.07.014 · Cited by 710
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
An overview of residual stresses in metal powder bed fusion
Bartlett, J. L., & Li, X. (2019) · Additive Manufacturing · doi:10.1016/j.addma.2019.02.020 · Cited by 616
Metadata
- Authors
- Stoney, G. G.
- Venue
- Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character
- Publisher
- The Royal Society
- Published
- 1909-05-06
- Volume
- 82
- Issue
- 553
- Pages
- 172-175
- ISSN
- 0950-1207 (ISSN-L)
- 2053-9150
- OpenAlex
- W2066874036
- Cited by
- 4,872
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The tension of metallic films deposited by electrolysis. https://app.cochat.ai/papers/10.1098/rspa.1909.0021
- The paper
- Stoney, G. G. (1909). The tension of metallic films deposited by electrolysis. Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character. https://doi.org/10.1098/rspa.1909.0021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.