The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
The selection of mechanical actuators based on performance indices
Abstract
A method is presented for selecting the type of actuator best suited to a given task, in the early stages of engineering design. The selection is based on matching performance characteristics of the actuator, such as force and displacement, to the requirements of the given task. The performance characteristics are estimated from manufacturers' data and from simple models of performance limitation such as heat generation and resonance. Characteristics are presented in a graphical form which allows for a direct and systematic comparison of widely different systems of actuation. The actuators considered include man-made actuators (such as hydraulic, solenoid and shape memory alloy) and naturally occurring actuators (such as the muscles of animals and plants).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smithells Metals Reference Book
(1992) · Elsevier eBooks · doi:10.1016/c2009-0-25363-3 · Cited by 3,613
Materials Selection in Mechanical Design
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-25539-5 · Cited by 2,679
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602
Engineering Aspects of Shape Memory Alloys
(1990) · Elsevier eBooks · doi:10.1016/c2013-0-04566-5 · Cited by 1,516
Ferroelectric Materials and Their Applications
(2016) · Japanese Journal of Applied Physics · doi:10.7567/jjap.55.10t001 · Cited by 1,368
Fundamentals of Piezoelectricity
(2006) · Advances in Industrial Control · doi:10.1007/1-84628-332-9_2 · Cited by 1,149
Muscles, Reflexes, and Locomotion
McMahon, T. A. (1984) · Princeton University Press eBooks · doi:10.1515/9780691221540 · Cited by 1,025
Thermomechanical aspects of NiTi
Shaw, J. A. (1995) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(95)00024-d · Cited by 971
Energetic aspects of muscle contraction
(1986) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(86)90238-7 · Cited by 736
Wilkins, M. B. (1988) · Cited by 537
Cited by
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Soft material for soft actuators
Miriyev, A., Stack, K., & Lipson, H. (2017) · Nature Communications · doi:10.1038/s41467-017-00685-3 · Cited by 861
Photomechanical actuation in polymer–nanotube composites
Ahir, S. V., & Terentjev, E. M. (2005) · Nature Materials · doi:10.1038/nmat1391 · Cited by 423
Metadata
- Authors
- Huber, J. E., Fleck, N. A., & Ashby, M. F.
- Venue
- Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 1997-10-08
- Volume
- 453
- Issue
- 1965
- Pages
- 2185-2205
- ISSN
- 1364-5021 (ISSN-L)
- 1471-2946
- OpenAlex
- W2093061150
- Cited by
- 508
- References
- 17
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The selection of mechanical actuators based on performance indices. https://app.cochat.ai/papers/10.1098/rspa.1997.0117
- The paper
- Huber, J. E., Fleck, N. A., & Ashby, M. F. (1997). The selection of mechanical actuators based on performance indices. Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences. https://doi.org/10.1098/rspa.1997.0117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.