CoChat

Muscular exercise, lactic acid, and the supply and utilisation of oxygen.—Parts IV-VI

Open access
Hill, Archibald Vivian, Long, C. N. H., Lupton, H. · 1924 · Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character
Cited by 146

The DOI matches its Crossref record.

Abstract

The method of studying the respiratory exchanges of man employed throughout our investigation has been that of the Douglas bag. No other method allows the same facility and accuracy in following a rapidly altering oxygen intake and carbon dioxide output. We have found it possible, during and after muscular exercise, to work with periods of collection of half a minute, and even, on occasions when it was necessary, of quarter of a minute. This makes it possible to analyse accurately the rapid alterations of oxygen intake and carbon dioxide output which occur at the beginning and at the end of muscular exercise. The gas analyses have been carried out by the ordinary Haldane’s gas analysis apparatus (large laboratory type) except in certain later experiments, where a modification (in which the gas is bubbled through the pyrogallol) introduced by D. T. Harris was used. The bags employed have been of various types, varying in capacity from 30 to 2,000 litres. They have all—some 25 of them—been made for us specially by Messrs. C. Macintosh & Co., of Cambridge Street, Manchester, and have proved an essential part of our equipment. We are glad to take this opportunity of expressing to the Company, and especially to Mr. J. S. Corker, a director, our most sincere thanks for the courtesy, completeness and expedition with which all our needs have been supplied. Some of these bags especially the smallest, but including two of 500 litres capacity, have been of the ordinary flat type as used by Douglas. Others of 150 to 300 litres capacity, employed for collecting the expired air during running or walking, have been of a truncated wedge shape, carried like a Rücksack on the back, with a sidepipe low down on the left-hand side, to enable the tap to be carried freely the left hand. (See fig. 1.) A third type (400 and 500 litres), roughly cubical in shape, was employed for prolonged collection of expired gases during recovery from muscular exercise. A fourth type (1,000 and 2,000 litres) was used, in experiments to be described later, to contain the inspired gas mixture, which on expiration was collected in bags of the other types. These may be used also to follow very prolonged recovery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rspb.1924.0045

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hill, A. V., Long, C. N. H., & Lupton, H.
Venue
Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character
Published
1924-11-01
Volume
97
Issue
681
Pages
84-138
ISSN
  • 0950-1193 (ISSN-L)
  • 2053-9185
OpenAlex
W4255608656
Cited by
146
References
0
FWCI
3.79
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.