CoChat

The thickness of the myelin sheaths of normal and regenerating peripheral nerve fibres

Sanders, F. K. · 1948 · Proceedings of the Royal Society of London. Series B - Biological Sciences
Cited by 100

The DOI matches its Crossref record.

Abstract

An investigation has been made of the relation between axon diameter, fibre diameter, and myelin sheath thickness in myelinated nerve fibres from the peroneal nerve of the rabbit. Fibres were measured: (a) in the normal nerve, and (b) during regeneration following nerve crushing. In the normal nerve, fibres ranging in diameter from 1 to 20μ, were present. These had axons with diameters from 0·5μ in the smallest, to about 15μ in the largest fibres. The 0·5μ axons had myelin sheaths about 0·5μ thick, while the largest axons had sheaths about 2·5μ thick. Between these extremes the curve relating sheath thickness to axon diameter was at first steep, and then more gradual in slope. In regenerating nerve fibres 15 mm. proximal to the site of lesion the axons decline steadily in diameter during the first period of regeneration (100 days). Thereafter they increase in size, although even after 300 days the largest axons have not regained their normal diameter. The axons, 10 mm. below the lesion, extremely thin at their first appearance, increase steadily in diameter, until, 300 days after injury they equal in diameter the axons of the proximal stump. The decrease in diameter of axons proximally is accompanied by an absolute increase in their myelin sheath thickness. This takes place first of all without any alteration in the total diameter of the fibres concerned, the increase in thickness of the myelin compensating the decrease in axon diameter. Between 60 and 100 days after injury, however, continuing axon decrease is accompanied by a decrease in the total diameter of the fibres. Between 100 and 200 days an increase in total fibre diameter parallels the increase in axon diameter, the myelin sheaths remaining abnormally thick. Between 200 and 300 days after injury the continued increase in axon diameter causes a diminution in myelin sheath thickness. Even at 300 days after injury, however, the sheaths are still thicker than in normal nerve. In the distal stump the myelin sheaths, when first developed, are thicker than those of fibres of corresponding diameter in normal nerve. Subsequently they grow still thicker, reaching their maximum thickness about 200 days after nerve injury. Between 200 and 300 days a slight diminution in sheath thickness occurs since the axons continue to increase while the total diameter remains the same. However, even at 300 days the sheaths are still thicker than normal. The bearing of these results on the nature of the forces maintaining the structure of nerve fibres is discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rspb.1948.0015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 100

Metadata

Authors
Sanders, F. K.
Venue
Proceedings of the Royal Society of London. Series B - Biological Sciences
Published
1948-10-26
Volume
135
Issue
880
Pages
323-357
ISSN
  • 0080-4649 (ISSN-L)
  • 2053-9193
OpenAlex
W2156266724
Cited by
100
References
0
FWCI
2.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The thickness of the myelin sheaths of normal and regenerating peripheral nerve fibres. https://app.cochat.ai/papers/10.1098/rspb.1948.0015
The paper
Sanders, F. K. (1948). The thickness of the myelin sheaths of normal and regenerating peripheral nerve fibres. Proceedings of the Royal Society of London. Series B - Biological Sciences. https://doi.org/10.1098/rspb.1948.0015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.