Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 355

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Linear electrical properties of striated muscle fibres observed with intracellular electrodes

Falk, G., Fatt, Paul·1964·Proceedings of the Royal Society of London. Series B. Biological Sciences

Abstract

The linear electrical properties of muscle fibres have been examined using intracellular electrodes for a. c. measurements and analyzing observations on the basis of cable theory. The measurements have covered the frequency range 1 c/s to 10 kc/s. Comparison of the theory for the circular cylindrical fibre with that for the ideal, one-dimensional cable indicates that, under the conditions of the experiments, no serious error would be introduced in the analysis by the geometrical idealization. The impedance locus for frog sartorius and crayfish limb muscle fibres deviates over a wide range of frequencies from that expected for a simple model in which the current path between the inside and the outside of the fibre consists only of a resistance and a capacitance in parallel. A good fit of the experimental results on frog fibres is obtained if the inside-outside admittance is considered to contain, in addition to the parallel elements Rm = 3100 Ωcm2 and Cm = 2.6 μF/cm2, another path composed of a resistance Re = 330 Ωcm2 in series with a capacitance Ce = 4.1 μF/cm2, all referred to unit area of fibre surface. The impedance behaviour of crayfish fibres can be described by a similar model, the corresponding values being Rm = 680 Ωcm2, Cm = 3.9 μF/cm2, Re = 35 Ωcm2, Ce = 17 μF/cm2. The response of frog fibres to a step-function current (with the points of voltage recording and current application close together) has been analyzed in terms of the above two-time constant model, and it is shown that neglecting the series resistance would have an appreciable effect on the agreement between theory and experiment only at times less than the halftime of rise of the response. The elements Rm and Cm are presumed to represent properties of the surface membrane of the fibre. Re and Ce are thought to arise not at the surface, but to be indicative of a separate current path from the myoplasm through an intracellular system of channels to the exterior. In the case of crayfish fibres, it is possible that Re (when referred to unit volume) would be a measure of the resistivity of the interior of the channels, and Ce the capacitance across the walls of the channels. In the case of frog fibres, it is suggested that the elements Re, Ce arise from the properties of adjacent membranes of the triads in the sarcoplasmic reticulum . The possibility is considered that the potential difference across the capacitance Ce may control the initiation of contraction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rspb.1964.0030

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 355

Metadata

Authors
Falk, G., & Fatt, P.
Venue
Proceedings of the Royal Society of London. Series B. Biological Sciences
Published
1964-04-14
Volume
160
Issue
978
Pages
69-123
ISSN
  • 0080-4649 (ISSN-L)
  • 2053-9193
OpenAlex
W1972122733
Cited by
355
References
19
FWCI
6.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Linear electrical properties of striated muscle fibres observed with intracellular electrodes. https://app.cochat.ai/papers/10.1098/rspb.1964.0030
The paper
Falk, G., & Fatt, P. (1964). Linear electrical properties of striated muscle fibres observed with intracellular electrodes. Proceedings of the Royal Society of London. Series B. Biological Sciences. https://doi.org/10.1098/rspb.1964.0030

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.