The DOI matches its Crossref record.
Voltage clamp analysis of acetylcholine produced end‐plate current fluctuations at frog neuromuscular junction
Open accessAbstract
1. Acetylcholine produced end‐plate current (e.p.c.) noise is shown to be the results of statistical fluctuations in the ionic conductance of voltage clamped end‐plates of Rana pipiens. 2. These e.p.c. fluctuations are characterized by their e.p.c. spectra which conform to a relation predicted from a simple model of end‐plate channel gating behaviour. 3. The rate constant of channel closing α is determined from e.p.c. spectra and is found to depend on membrane potential V according to the relation α = B e AV (B = 0·17 msec−1±0·04 S.E., A = 0·0058 mV−1±0·0009 S.E. at 8° C) and to vary with temperature T with a Q10 = 2·77, at −70 mV. A and B in this expression both vary with T and therefore produce a membrane potential dependent Q10 for α. 4. Nerve‐evoked e.p.c.s and spontaneous miniature e.p.c.s decay exponentially in time with a rate constant which depends exponentially on V. The magnitude and voltage dependence of this decay constant is exactly that found from e.p.c. spectra for the channel closing rate α. 5. The conductance γ of a single open end‐plate channel has been estimated from e.p.c. spectra and is found not to be detectibly dependent on membrane potential, temperature and mean end‐plate current. γ = 0·32±0·0045 ( S.E.) × 10−10 mhos. Some variation in values for γ occurs from muscle to muscle. 6. It is concluded that the relaxation kinetics of open ACh sensitive ionic channels is the rate limiting step in the decay of synaptic current and that this channel closing has a single time constant. The relaxation rate is independent of how it is estimated (ACh produced e.p.c. fluctuations, e.p.c., m.e.p.c.), and is consistent with the hypothesis that individual ionic channels open rapidly to a specific conductance which remains constant for an exponentially distributed duration. 7. The voltage and temperature dependence of the channel closing rate constant agree with the predictions of a simple dipole‐conformation change model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Responses of retinal rods to single photons.
Baylor, D. A., Lamb, T. D., & Yau, K. W. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012716 · Cited by 992
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Study, R. E., & Barker, J. L. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.11.7180 · Cited by 561
Intracellular Ca2+ activates a fast voltage-sensitive K+ current in vertebrate sympathetic neurones
Adams, P. R., Constanti, A., Brown, D. A., & Clark, R. B. (1982) · Nature · doi:10.1038/296746a0 · Cited by 417
Colquhoun, D., & Sakmann, B. (1981) · Nature · doi:10.1038/294464a0 · Cited by 353
Metadata
- Authors
- Anderson, C. R., & Stevens, C. F.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1973-12
- Volume
- 235
- Issue
- 3
- Pages
- 655-691
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1977106724
- Cited by
- 986
- References
- 0
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltage clamp analysis of acetylcholine produced end‐plate current fluctuations at frog neuromuscular junction. https://app.cochat.ai/papers/10.1113/jphysiol.1973.sp010410
- The paper
- Anderson, C. R., & Stevens, C. F. (1973). Voltage clamp analysis of acetylcholine produced end‐plate current fluctuations at frog neuromuscular junction. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1973.sp010410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.