Biological microtribology: anisotropy in frictional forces of orthopteran attachment pads reflects the ultrastructure of a highly deformable material
Open accessThe DOI matches its Crossref record.
Abstract
Evolutionarily optimized frictional devices of insects are usually adapted to attach to a variety of natural surfaces. Orthopteran attachment pads are composed of hexagonal outgrowths with smooth flexible surfaces. The pads are designed to balance the weight of the insect in different positions and on different materials. In a scanning electron microscopy study followed by freezing-substitution experiments, the ultrastructural architecture of the pad material was visualized. In friction experiments, the interaction was measured between the attachment pad and a polished silicon surface. The inner structure of this material contains distally directed rods, branching close to the surface, and spaces filled with fluid. The specific design of the pad material provides a higher frictional force in the distal direction. Frictional anisotropy is more enhanced at higher normal forces and lower sliding velocities. It is concluded that optimal mechanical functionality of biosystems is the result of a combination of surface structuring and material design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gecko‐Inspired Surfaces: A Path to Strong and Reversible Dry Adhesives
Boesel, L. F., Greiner, C., Arzt, E., & del Campo, A. (2010) · Advanced Materials · doi:10.1002/adma.200903200 · Cited by 472
Beutel, R. G., & Gorb, S. N. (2001) · Journal of Zoological Systematics and Evolutionary Research · doi:10.1046/j.1439-0469.2001.00155.x · Cited by 461
Self-citationAn Integrative Study of Insect Adhesion: Mechanics and Wet Adhesion of Pretarsal Pads in Ants
Federle, W. (2002) · Integrative and Comparative Biology · doi:10.1093/icb/42.6.1100 · Cited by 366
Biologically inspired crack trapping for enhanced adhesion
Glassmaker, N. J., Jagota, A., Hui, C.-Y., Noderer, W. L., & Chaudhury, M. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703762104 · Cited by 258
Drechsler, P., & Federle, W. (2006) · Journal of Comparative Physiology A · doi:10.1007/s00359-006-0150-5 · Cited by 214
“As in adhesive pads of other insects, contact area and friction forces are maximal in this direction (bushcrickets: Gorb and Scherge 2000; Xies: Niederegger et al. 2002; ants: Federle et al. 2001; Federle and Endlein 2004).”
BackgroundResultInfluentialStructural Design and Biomechanics of Friction-Based Releasable Attachment Devices in Insects
Gorb, S. N. (2002) · Integrative and Comparative Biology · doi:10.1093/icb/42.6.1127 · Cited by 200
Self-citationBullock, J. M. R., Drechsler, P., & Federle, W. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.020941 · Cited by 172
“THE JOURNAL OF EXPERIMENTAL BIOLOGY 3334 smooth adhesive pads of ants, bushcrickets and cockroaches (Clemente and Federle, 2008; Federle et al., 2001; Federle and Endlein, 2004; Gorb and Scherge, 2000).”
Background
Metadata
- Authors
- Gorb, S., & Scherge, M.
- Venue
- Proceedings of the Royal Society of London. Series B: Biological Sciences
- Publisher
- The Royal Society
- Published
- 2000-06-22
- Volume
- 267
- Issue
- 1449
- Pages
- 1239-1244
- ISSN
- 0080-4649 (ISSN-L)
- 0962-8452
- 1471-2954
- OpenAlex
- W2157733845
- Cited by
- 149
- References
- 0
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.