Towards biodegradable wireless implants
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A new generation of partially or even fully biodegradable implants is emerging. The idea of using temporary devices is to avoid a second surgery to remove the implant after its period of use, thereby improving considerably the patient's comfort and safety. This paper provides a state-of-the-art overview and an experimental section that describes the key technological challenges for making biodegradable devices. The general considerations for the design and synthesis of biodegradable components are illustrated with radiofrequency-driven resistor–inductor–capacitor (RLC) resonators made of biodegradable metals (Mg, Mg alloy, Fe, Fe alloys) and biodegradable conductive polymer composites (polycaprolactone–polypyrrole, polylactide–polypyrrole). Two concepts for partially/fully biodegradable wireless implants are discussed, the ultimate goal being to obtain a fully biodegradable sensor for in vivo sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications
Lee, J. Y., Bashur, C. A., Goldstein, A. S., & Schmidt, C. E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.042 · Cited by 735
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Cited by
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring
Boutry, C. M., Nguyen, A., Lawal, Q. O., Chortos, A., Rondeau‐Gagné, S., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201502535 · Cited by 647
Self-citationZarei, M., Lee, G., Lee, S. G., & Cho, K. (2023) · Advanced Materials · doi:10.1002/adma.202203193 · Cited by 345
Choi, Y. S., Hsueh, Y.-Y., Koo, J., Yang, Q., Avila, R., Hu, B., Xie, Z., Lee, G., Ning, Z., Liu, C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19660-6 · Cited by 292
LC Passive Wireless Sensors Toward a Wireless Sensing Platform: Status, Prospects, and Challenges
Huang, Q.-A., Dong, L., & Wang, L.-F. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2602298 · Cited by 284
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Shin, J., Yan, Y., Bai, W., Xue, Y., Gamble, P., Tian, L., Kandela, I., Haney, C. R., Spees, W., Lee, Y., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0300-4 · Cited by 263
Metadata
- Authors
- Boutry, C. M., Chandrahalim, H., Streit, P., Schinhammer, M., Hänzi, A. C., & Hierold, C.
- Venue
- Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2012-05-28
- Volume
- 370
- Issue
- 1967
- Pages
- 2418-2432
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W2108692265
- Cited by
- 80
- References
- 5
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.