Electron-transfer biosensors
The DOI matches its Crossref record.
Abstract
The electrochemistry of redox proteins is now well established. Conditions exist which allow electron-transfer reactions of all simple proteins to proceed rapidly and reversibly at electrodes. Coupling of the electrode reaction to enzymes, for which the redox proteins act as cofactors, allows exploitation of this good electrochemistry. This is well illustrated by the enzyme-catalysed electrochemical oxidation of p-cresol to p-hydroxybenzaldehyde, which has been shown to proceed along with coupling to the electrode via the copper protein, azurin, or the organometallic compound ferroceneboronic acid. Ferrocene derivatives, in general, show a degree of versatility, coupling the electron-transfer reactions of many enzymes. Thus derivatives of the ferricinium ion act as excellent electron-transfer reagents from the enzyme glucose oxidase. The system is capable of detecting glucose in blood. Similar procedures, in conjunction with the appropriate enzyme, have yielded assays for, among others, H2O2 and cholesterol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
“They were extensively studied as electron-shuttling mediators between both GOx and GDH-PQQ and the electrodes [50,54-56].”
BackgroundSilver, I., & Erecinska, M. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-08-05068.1994 · Cited by 477
Biosensors for chemical and biological agents of defence interest
Paddle, B. M. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)82333-5 · Cited by 240
Glucose-Induced Intracellular Ion Changes in Sugar-Sensitive Hypothalamic Neurons
Silver, I. A., & Erecinska, M. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.4.1733 · Cited by 210
“Total blood sugarrange of glucose concentrations 0.1–40 mM and is insensitive was determined periodically from the other 20 ml by the methodto changes in oxygen concentration (Frew and Hill 1987).”
MethodInfluentialRecent Advancements in Nanobiosensors: Current Trends, Challenges, Applications, and Future Scope
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12100892 · Cited by 202
Enzyme-Based Biosensors: Tackling Electron Transfer Issues
Bollella, P., & Katz, E. (2020) · Sensors · doi:10.3390/s20123517 · Cited by 195
Biochemical aspects of biosensors
Byfield, M. P., & Abuknesha, R. A. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)80038-3 · Cited by 173
Metadata
- Authors
- Frew, J. E., & Hill, H. A. O.
- Venue
- Philosophical Transactions of the Royal Society of London. B, Biological Sciences
- Publisher
- The Royal Society
- Published
- 1987-08-28
- Volume
- 316
- Issue
- 1176
- Pages
- 95-106
- ISSN
- 0080-4622 (ISSN-L)
- 2054-0280
- OpenAlex
- W2141840734
- Cited by
- 49
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.