The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Statistical assessment of a laboratory method for growing biofilms
Abstract
Microbial biofilms have been grown in laboratories using a variety of different approaches. A laboratory biofilm reactor system, called the CDC biofilm reactor (CBR) system, has been devised for growing biofilms under moderate to high fluid shear stress. The reactor incorporates 24 removable biofilm growth surfaces (coupons) for sampling and analysing the biofilm. Following preliminary experiments to verify the utility of the CBR system for growing biofilms of several clinically relevant organisms, a standard operating procedure for growing a Pseudomonas aeruginosa biofilm was created. This paper presents the results of a rigorous, intra-laboratory, statistical evaluation of the repeatability and ruggedness of that procedure as well as the results of the experiments with clinically relevant organisms. For the statistical evaluations, the outcome of interest was the density (c.f.u. cm−2) of viable P. aeruginosa. Replicate experiments were conducted to assess the repeatability of the log density outcome. The mean P. aeruginosa log 10 density was 7·1, independent of the coupon position within the reactor. The repeatability standard deviation of the log density based on one coupon per experiment was 0·59. Analysis of variance showed that the variability of the log density was 53 % attributable to within-experiment sources and 47 % attributable to between-experiments sources. The ruggedness evaluation applied response-surface design and regression analysis techniques, similar to those often used for sensitivity analyses in other fields of science and engineering. This approach provided a quantitative description of ruggedness; specifically, the amount the log density was altered by small adjustments to four key operational factors – time allowed for initial surface colonization, temperature, nutrient concentration, and fluid shear stress on the biofilm. The small size of the regression coefficient associated with each operational factor showed that the method was rugged; that is, relatively insensitive to minor perturbations of the four factors. These results demonstrate that the CBR system is a reliable experimental tool for growing a standard biofilm in the laboratory and that it can be adapted to study several different micro-organisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
Standard, S. (2006) · Cited by 6,460
O'Toole, G. A., & Kolter, R. (1998) · Molecular Microbiology · doi:10.1046/j.1365-2958.1998.00797.x · Cited by 2,537
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Ceri, H., Olson, M. E., Stremick, C., Read, R. R., Morck, D., & Buret, A. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.6.1771-1776.1999 · Cited by 2,155
How to optimize the drop plate method for enumerating bacteria
Herigstad, B., Hamilton, M., & Heersink, J. (2001) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(00)00241-4 · Cited by 965
Self-citationFeldsine, P., Abeyta, C., & Andrews, W. H. (2002) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/85.5.1187 · Cited by 444
Influence of hydrodynamics and nutrients on biofilm structure
Stoodley, P., Dodds, I., Boyle, J. D., & Lappin-Scott, H. M. (1998) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.1998.tb05279.x · Cited by 407
Statistical Manual of the Association of Official Analytical Chemists
Steiner, E. H., & Youden, W. J. (1984) · Medical Entomology and Zoology · Cited by 388
Role of biofilms in the survival of Legionella pneumophila in a model potable-water system
Murga, R., Pruckler, J. M., Forster, T. S., et al. (2001) · Microbiology · doi:10.1099/00221287-147-11-3121 · Cited by 325
Self-citationModel System for Growing and Quantifying Streptococcus pneumoniae Biofilms In Situ and in Real Time
Donlan, R. M., Piede, J. A., Heyes, C. D., Sanii, L. S., Murga, R., Edmonds, P., El‐Sayed, I. H., & El‐Sayed, M. A. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.8.4980-4988.2004 · Cited by 150
Self-citation
Cited by
Bacterial adherence and biofilm formation on medical implants: A review
Veerachamy, S., Yarlagadda, T., Manivasagam, G., & Yarlagadda, P. K. (2014) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411914556137 · Cited by 583
In vitro and in vivo model systems to study microbial biofilm formation
Coenye, T., & Nelis, H. J. (2010) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2010.08.018 · Cited by 463
Marchand, S., De Block, J., De Jonghe, V., Coorevits, A., Heyndrickx, M., & Herman, L. (2012) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/j.1541-4337.2011.00183.x · Cited by 350
Haney, E., Trimble, M., Cheng, J., Vallé, Q., & Hancock, R. (2018) · Biomolecules · doi:10.3390/biom8020029 · Cited by 308
Harrison, J. J., Stremick, C. A., Turner, R. J., Allan, N. D., Olson, M. E., & Ceri, H. (2010) · Nature Protocols · doi:10.1038/nprot.2010.71 · Cited by 286
Metadata
- Authors
- Goeres, D. M., Loetterle, L. R., Hamilton, M. A., Murga, R., Kirby, D. W., & Donlan, R. M.
- Venue
- Microbiology
- Publisher
- Microbiology Society
- Published
- 2005-03-01
- Volume
- 151
- Issue
- 3
- Pages
- 757-762
- ISSN
- 1350-0872 (ISSN-L)
- 1465-2080
- OpenAlex
- W2132914602
- Cited by
- 271
- References
- 16
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistical assessment of a laboratory method for growing biofilms. https://app.cochat.ai/papers/10.1099/mic.0.27709-0
- The paper
- Goeres, D. M., Loetterle, L. R., Hamilton, M. A., Murga, R., Kirby, D. W., & Donlan, R. M. (2005). Statistical assessment of a laboratory method for growing biofilms. Microbiology. https://doi.org/10.1099/mic.0.27709-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.