The DOI matches its Crossref record.
Validity of Wrist and Forehead Temperature in Temperature Screening in the General Population During the Outbreak of 2019 Novel Coronavirus: a prospective real-world study
Open accessPreprint — published as 10.18502/ijph.v49is1.3670
Abstract
Aims: Temperature screening is important in the population during the outbreak of 2019 Novel Coronavirus (COVID-19). This study aimed to compare the accuracy and precision of wrist and forehead temperature with tympanic temperature under different circumstances. Methods: We performed a prospective observational study in a real-life population. We consecutively collected wrist and forehead temperatures in Celsius (°C) using a non-contact infrared thermometer (NCIT). We also measured the tympanic temperature using a tympanic thermometers (IRTT) and defined fever as a tympanic temperature ≥37.3°C. Results: We enrolled a total of 528 participants including 261 indoor and 267 outdoor participants. We divided outdoor participants into four types according to their means of transportation to the hospital as walk, bicycle, electric vehicle, car, and inside the car. Under different circumstance, the mean difference ranged from −1.72 to −0.56°C in different groups for the forehead measurements, and −0.96 to −0.61°C for the wrist measurements. Both measurements had high fever screening abilities in inpatients (wrist: AUC 0.790; 95% CI: 0.725-0.854, P <0.001; forehead: AUC 0.816; 95% CI: 0.757-0.876, P <0.001). The cut-off value of wrist measurement for detecting tympanic temperature ≥37.3°C was 36.2°C with a 86.4% sensitivity and a 67.0% specificity, and the best threshold of forehead measurement was also 36.2°C with a 93.2% sensitivity and a 60.0% specificity. Conclusions: Wrist measurement is more stable than forehead measurement under different circumstance. Both measurements have great fever screening abilities for indoor patients. The cut-off value of both measurements was 36.2°C. ( ClinicalTrials.gov number: NCT04274621 )
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Previous studies using clinical data from hospitals and transit centers have been inconclusive regarding the use and effectiveness of NCITs as a screening method during SARS and influenza outbreaks.
“Overall, previous studies using clinical data from hospitals and transit centers have been inconclusive regarding the use and effectiveness of NCITs as a screening method during SARS and influenza outbreaks.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [10]
Chen et al. found the mean difference between forehead and tympanic temperature ranged from −1.72 to −0.56 °C.
“The mean difference ranged from − 1.72 to − 0.56 °C.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [10]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 16
- Zumla A , Hui DS , Azhar EI , Memish ZA , Maeurer M. Reducing mortality from 2019-nCoV: host-directed therapies should be an option. The Lancet 2020. · DOI · Paper page
- Wu JT , Leung K , Leung GM . Nowcasting and forecasting the potential domestic and international spread of the 2019-nCoV outbreak originating in Wuhan, China: a modelling study. The Lancet 2020. · DOI · Paper page
- Wang W , Tang J , Wei F. Updated understanding of the outbreak of 2019 novel coronavirus (2019-nCoV) in Wuhan, China. Journal of Medical Virology 2020. · DOI
- Wang D , Hu B , Hu C , Zhu F , Liu X , Zhang J , et al. Clinical characteristics of 138 hospitalized patients with 2019 novel coronavirus–infected pneumonia in Wuhan, China. Jama 2020. · DOI · Paper page
- Guan W-j , Ni Z-y , Hu Y , Liang W-h , Ou C-q , He J-x , et al. Clinical characteristics of 2019 novel coronavirus infection in China. medRxiv 2020. · DOI
- 10.1097/PEC.0b013e31802c61e6 · DOI
- 2018, Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes, BMC pediatrics, 18, 15, 10.1186/s12887-018-0994-1 · DOI
- 2013, Skin temperature measurement using an infrared thermometer on patients who have been exposed to cold, Pediatrics International, 55, 767, 10.1111/ped.12188 · DOI
- Holt S , Yo J , Karschimkus C , Volpato F , Christov S , Smith E , et al. Monitoring skin temperature at the wrist in hospitalised patients may assist in the detection of infection. Internal Medicine Journal 2020. · DOI · Paper page
- 2008, Body temperature and its regulation, Anaesthesia & Intensive Care Medicine, 9, 259, 10.1016/j.mpaic.2008.04.009 · DOI
- 2013, Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer, BMC research notes, 6, 194, 10.1186/1756-0500-6-194 · DOI
- 10.1177/096228029900800204 · DOI · Paper page
- 10.1097/00000539-200207000-00012 · DOI
- 2018, Comparison of infrared tympanic, non-contact infrared skin, and axillary thermometer to rectal temperature measurements in a pediatric emergency observation unit, Int J Clin Exp Med, 11, 567
- 2010, Tympanic temperature comparison with oral mercury thermometer readings in an OPD setting, J Coll Physicians Surg Pak, 20, 33
- Vesnovsky O , Li Y , Topoleski L , Zhu L. Modeling of Differences Between Body Core and Forehead Temperatures Measured by Infrared Thermometers. In: 2017 Design of Medical Devices Conference; 2017: American Society of Mechanical Engineers Digital Collection; 2017. · DOI
Cited by
Sorted by citations
Clinical evaluation of non-contact infrared thermometers
Sullivan, S. J. L., Rinaldi, J. E., Hariharan, P., Casamento, J. P., Baek, S., Seay, N., Vesnovsky, O., & Topoleski, L. D. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-99300-1 · Cited by 44
Metadata
- Authors
- Chen, G., Xie, J., Dai, G., Zheng, P., Hu, X., Lu, H., Xu, L., Chen, X., & Chen, X.
- Affiliations
- Ningbo First Hospital (CN)
- Corresponding author
- Chen, Xueqin
- Chen, Xiaomin
- Venue
- Iranian Journal of Public Health
- Publisher
- openRxiv
- Published
- 2020-03-06
- Volume
- 49
- Issue
- Suppl 1
- Pages
- 57-66
- ISSN
- 0304-4556 (ISSN-L)
- PMC
- PMC8266026
- OpenAlex
- W3031551593
- Cited by
- 40
- References
- 0
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 6 · 2022: 10 · 2021: 14 · 2020: 4
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Iranian Journal of Public Health (publishedVersion, cc-by-nc)
- medRxiv (acceptedVersion)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Keywords
- COVID-19 pandemic, fever screening, wrist temperature, forehead temperature, tympanic temperature, cut-off values, sensitivity and specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review