The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization.
Open accessAbstract
The 5' nuclease PCR assay detects the accumulation of specific PCR product by hybridization and cleavage of a double-labeled fluorogenic probe during the amplification reaction. The probe is an oligonucleotide with both a reporter fluorescent dye and a quencher dye attached. An increase in reporter fluorescence intensity indicates that the probe has hybridized to the target PCR product and has been cleaved by the 5'-->3' nucleolytic activity of Taq DNA polymerase. In this study, probes with the quencher dye attached to an internal nucleotide were compared with probes with the quencher dye attached to the 3'-end nucleotide. In all cases, the reporter dye was attached to the 5' end. All intact probes showed quenching of the reporter fluorescence. In general, probes with the quencher dye attached to the 3'-end nucleotide exhibited a larger signal in the 5' nuclease PCR assay than the internally labeled probes. It is proposed that the larger signal is caused by increased likelihood of cleavage by Taq DNA polymerase when the probe is hybridized to a template strand during PCR. Probes with the quencher dye attached to the 3'-end nucleotide also exhibited an increase in reporter fluorescence intensity when hybridized to a complementary strand. Thus, oligonucleotides with reporter and quencher dyes attached at opposite ends can be used as homogeneous hybridization probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
Energy transfer: a spectroscopic ruler.
Stryer, L., & Haugland, R. P. (1967) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.58.2.719 · Cited by 1,957
Allelic discrimination by nick-translation PCR with fluorgenic probes
Lee, L. G., Connell, C. R., & Bloch, W. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.16.3761 · Cited by 749
Nakajima-Iijima, S., Hamada, H., Reddy, P., & Kakunaga, T. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.18.6133 · Cited by 691
Structure-Specific Endonucleolytic Cleavage of Nucleic Acids by Eubacterial DNA Polymerases
Lyamichev, V., Brow, M. A. D., & Dahlberg, J. E. (1993) · Science · doi:10.1126/science.7683443 · Cited by 367
Cited by
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Self-citationMolecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Lanthanide Luminescence for Biomedical Analyses and Imaging
Bünzli, J.-C. G. (2010) · Chemical Reviews · doi:10.1021/cr900362e · Cited by 2,690
A novel method for real time quantitative RT-PCR.
Gibson, U. E., Heid, C. A., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.995 · Cited by 2,075
The Transcriptional Program in the Response of Human Fibroblasts to Serum
Iyer, V. R., Eisen, M. B., Ross, D. T., Schuler, G., Moore, T., Lee, J. C. F., Trent, J. M., Staudt, L. M., Hudson, J., Boguski, M. S., et al. (1999) · Science · doi:10.1126/science.283.5398.83 · Cited by 1,965
Metadata
- Authors
- Livak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K.
- Venue
- Genome Research
- Publisher
- Cold Spring Harbor Laboratory
- Published
- 1995-06-01
- Volume
- 4
- Issue
- 6
- Pages
- 357-362
- ISSN
- 1088-9051 (ISSN-L)
- OpenAlex
- W1994091239
- Cited by
- 1,603
- References
- 6
- Type
- posted content
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.