Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 2,128

The DOI matches its Crossref record.

Hematoxylin and Eosin Staining of Tissue and Cell Sections

Fischer, Andrew H., Jacobson, Kenneth A., Rose, Jack, Zeller, Rolf·2008·Cold Spring Harbor Protocols

Abstract

INTRODUCTION: Hematoxylin and eosin (H&E) stains have been used for at least a century and are still essential for recognizing various tissue types and the morphologic changes that form the basis of contemporary cancer diagnosis. The stain has been unchanged for many years because it works well with a variety of fixatives and displays a broad range of cytoplasmic, nuclear, and extracellular matrix features. Hematoxylin has a deep blue-purple color and stains nucleic acids by a complex, incompletely understood reaction. Eosin is pink and stains proteins nonspecifically. In a typical tissue, nuclei are stained blue, whereas the cytoplasm and extracellular matrix have varying degrees of pink staining. Well-fixed cells show considerable intranuclear detail. Nuclei show varying cell-type- and cancer-type-specific patterns of condensation of heterochromatin (hematoxylin staining) that are diagnostically very important. Nucleoli stain with eosin. If abundant polyribosomes are present, the cytoplasm will have a distinct blue cast. The Golgi zone can be tentatively identified by the absence of staining in a region next to the nucleus. Thus, the stain discloses abundant structural information, with specific functional implications. A limitation of hematoxylin staining is that it is incompatible with immunofluorescence. It is useful, however, to stain one serial paraffin section from a tissue in which immunofluorescence will be performed. Hematoxylin, generally without eosin, is useful as a counterstain for many immunohistochemical or hybridization procedures that use colorimetric substrates (such as alkaline phosphatase or peroxidase). This protocol describes H&E staining of tissue and cell sections.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1101/pdb.prot4986

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 3

  1. Carson F.L. (1997) Histotechnology: A self-instructional text (ASCP Press, Chicago), 2nd ed.
  2. 10.1101/pdb.prot4987 · doi:10.1101/pdb.prot4987
  3. Sheehan D.C. Hrapchak B.B. (1980) Theory and practice of histotechnology (Battelle Press, Columbus, OH), 2nd ed.

Cited by

See all 2,128

Metadata

Authors
Fischer, A. H., Jacobson, K. A., Rose, J., & Zeller, R.
Venue
Cold Spring Harbor Protocols
Published
2008-05
Volume
2008
Issue
5
Pages
pdb.prot4986
ISSN
  • 1559-6095 (ISSN-L)
  • 1940-3402
OpenAlex
W2168056522
Cited by
2,128
References
0
Type
posted content
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hematoxylin and Eosin Staining of Tissue and Cell Sections. https://app.cochat.ai/papers/10.1101/pdb.prot4986
The paper
Fischer, A. H., Jacobson, K. A., Rose, J., & Zeller, R. (2008). Hematoxylin and Eosin Staining of Tissue and Cell Sections. Cold Spring Harbor Protocols. https://doi.org/10.1101/pdb.prot4986

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.