Adhesive Micropatterns for Cells: A Microcontact Printing Protocol
The DOI matches its Crossref record.
Abstract
INTRODUCTION: This protocol describes a simple, fast, and efficient method for making adhesive micropatterns that can be used to control individual cell shape and adhesion patterns. It is based on the use of an elastomeric stamp containing microfeatures to print proteins on the substrate of choice. The process can be subdivided into three parts. First, a silicon master is fabricated, which contains the microfeatures of interest. Once fabricated, the master can be used multiple times to make stamps. Masters with customized patterns can also be purchased commercially. Second, a polydimethylsiloxane (PDMS) stamp is fabricated. Unlike fabrication of the master, this step can be performed without specialized equipment. The PDMS stamp is inked with extracellular matrix proteins. Proteins are printed on a substrate (e.g., a tissue culture polystyrene dish or a glass coverslip covered with a thin layer of polystyrene). The nonprinted areas are back-filled with poly-L-lysine-polyethylene glycol, which renders them resistant to cell adhesion. The production of these micropatterned substrates can be completed in <2 h. The third and final portion of the protocol describes the deposition of cells onto the micropatterned substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micropatterning as a tool to decipher cell morphogenesis and functions
Théry, M. (2010) · Journal of Cell Science · doi:10.1242/jcs.075150 · Cited by 730
Self-citationCell volume change through water efflux impacts cell stiffness and stem cell fate
Guo, M., Pegoraro, A. F., Mao, A., Zhou, E. H., Arany, P. R., Han, Y., Burnette, D. T., Jensen, M. H., Kasza, K. E., Moore, J. R., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705179114 · Cited by 529
Self-organization of human embryonic stem cells on micropatterns
Deglincerti, A., Etoc, F., Guerra, M. C., Martyn, I., Metzger, J., Ruzo, A., Simunovic, M., Yoney, A., Brivanlou, A. H., Siggia, E., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.131 · Cited by 163
Protein kinase A governs a RhoA-RhoGDI protrusion-retraction pacemaker in migrating cells
Tkachenko, E., Sabouri-Ghomi, M., Pertz, O., Kim, C., Gutierrez, E., Machacek, M., Groisman, A., Danuser, G., & Ginsberg, M. H. (2011) · Nature Cell Biology · doi:10.1038/ncb2231 · Cited by 149
Substrate elasticity regulates the behavior of human monocyte-derived macrophages
Adlerz, K. M., Aranda-Espinoza, H., & Hayenga, H. N. (2016) · European Biophysics Journal · doi:10.1007/s00249-015-1096-8 · Cited by 135
Monitoring in vitro thrombus formation with novel microfluidic devices
Westein, E., de Witt, S., Lamers, M., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2012.709653 · Cited by 54
Metadata
- Authors
- Théry, M., & Piel, M.
- Venue
- Cold Spring Harbor Protocols
- Publisher
- Cold Spring Harbor Laboratory
- Published
- 2009-07
- Volume
- 2009
- Issue
- 7
- Pages
- pdb.prot5255
- ISSN
- 1559-6095 (ISSN-L)
- 1940-3402
- OpenAlex
- W2152235865
- Cited by
- 139
- References
- 0
- Type
- posted content
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.