CoChat

Detection, damping, and translating the center of the axial oscillation of a charged particle in a Penning trap with hyperbolic electrodes

Gabrielse, Gerald · 1984 · Physical Review A
Cited by 54

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The axial oscillation frequency of a trapped particle in a Penning trap with hyperbolic electrodes has proven to be a very important observable for precision experiments. Shifts in this frequency have been used to measure magnetron frequencies, cyclotron frequencies, and $g\ensuremath{-}2$ transitions for single trapped particles. Detection and damping of the axial oscillation were thought to be well understood except that a key constant which depends upon trap geometry had not been calculated. A relaxation calculation has thus been performed to provide a calculated value for this constant and several others, and to determine their dependence upon trap geometry. A surprising result is a discrepancy between the calculated value of the key constant and that deduced from measured values of the width of the axial oscillation frequency in the several cases where it has been measured.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.29.462

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Gabrielse, G.
Venue
Physical Review A
Published
1984-02-01
Volume
29
Issue
2
Pages
462-469
ISSN
0556-2791 (ISSN-L)
OpenAlex
W1990400206
Cited by
54
References
2
FWCI
3.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.