An experiment for the direct determination of the g-factor of a single proton in a Penning trap
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
A new apparatus has been designed that aims at a direct precision measurement of the g -factor of a single isolated proton or antiproton in a Penning trap. We present a thorough discussion on the trap design and a method for the experimental trap optimization using a single stored proton. A first attempt at the g -factor determination has been made in a section of the trap with a magnetic bottle. The Larmor frequency of the proton has been measured with a relative uncertainty of 1.8 × 10 −6 and the magnetic moment has been determined with a relative uncertainty of 8.9 × 10 −6 . A g -factor of 5.585 696(50) has been obtained, which is in excellent agreement with previous measurements and predictions. Future experiments shall drive the spin-flip transition in a section of the trap with a homogeneous magnetic field. This has the potential to improve the precision of the measured g -factor of the proton and the antiproton by several orders of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


























Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367 · cited 7×
“4), as demonstrated in [25].”
BackgroundMethodResultInfluentialThe Nuclear Induction Experiment
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.70.474 · Cited by 1,192
New measurement of the electron magnetic moment and the fine structure constant
Hanneke, D., Fogwell, S., & Gabrielse, G. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.120801 · Cited by 1,138
Recent trends in the determination of nuclear masses
Lunney, D., Pearson, J. M., & Thibault, C. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.1021 · Cited by 759
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685 · cited 1×
“Furthermore, Penning traps are crucial in the field of high-accuracy mass spectrometry [5–8].”
BackgroundSelf-citationNew high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
Open-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288 · cited 3×
“By means of a proper choice of the trap geometry and tuning ratio, C4 and C6 can be eliminated simultaneously, thus providing compensation of the potential in the lowest order [34, 35].”
BackgroundThousandfold improvement in the measured antiproton mass
Gabrielse, G., Fei, X., Orozco, L., Tjoelker, R., Haas, J., Kalinowsky, H., Trainor, T., & Kells, W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.1317 · Cited by 275
Research works printed but not linked: 4
- [27]27. Hermanspahn N H 1999 Das magnetische Moment des gebundenen Elektrons in wasserstoffartigem Kohlenstoff (C 5+ ) Dissertation Johannes Gutenberg-Universität Mainz
- [33]33. Bozorth R M 1993 Ferromagnetism (New York: Wiley-IEEE Press)
- [38]38. Verdú J 2003 Ultrapräzise Messung des elektronischen g-Faktors in wasserstoffähnlichem Sauerstoff Dissertation Johannes Gutenberg-Universität Mainz
- [39]39. Rodegheri C C 2012 Speicherung und Kühlung eines einzelnen Protons in einer Penning-Falle zur Bestimmung seines g-Faktors Dissertation Johannes Gutenberg-Universität Mainz (in preparation)
Cited by
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA Recommended Values of the Fundamental Physical Constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.4954402 · Cited by 252
Double-trap measurement of the proton magnetic moment at 0.3 parts per billion precision
Schneider, G. L., Mooser, A. H., Bohman, M., Schön, N., Harrington, J. A., Higuchi, T., Nagahama, H., Sellner, S., Smorra, C., Blaum, K., et al. (2017) · Science · doi:10.1126/science.aan0207 · Cited by 154
Self-citationOne-Particle Measurement of the Antiproton Magnetic Moment
DiSciacca, J., Marshall, M., Marable, K., Gabrielse, G., Ettenauer, S., Tardiff, E., Kalra, R., Fitzakerley, D. W., George, M. C., Hessels, E. A., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.130801 · Cited by 90
BASE – The Baryon Antibaryon Symmetry Experiment
Smorra, C., Blaum, K., Bojtár, L., Borchert, M. J., Franke, K., Higuchi, T., Leefer, N., Nagahama, H., Matsuda, Y., Mooser, A. H., et al. (2015) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2015-02607-4 · Cited by 105
Self-citation
Metadata
- Authors
- Rodegheri, C. C., Blaum, K., Kracke, H., Kreim, S., Mooser, A., Quint, W., Ulmer, S., & Walz, J.
- Affiliations
- Johannes Gutenberg University Mainz (DE)
- Heidelberg University (DE)
- GSI Helmholtz Centre for Heavy Ion Research (DE)
- Max Planck Institute for Nuclear Physics (DE)
- Corresponding author
- Rodegheri, C C
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2012-06-12
- Volume
- 14
- Issue
- 6
- Pages
- 063011
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W2096697046
- Semantic Scholar
- dfb6b3f07470f191e7cd1bfa5bf2233a007dcce8
- Cited by
- 37
- References
- 51
- Citations by year
- 2024: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 2
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- New Journal of Physics (publishedVersion, cc-by)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- European Commission
- Deutsche Forschungsgemeinschaft
- Bundesministerium für Bildung und Forschung
- Max-Planck-Gesellschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle physics theoretical and experimental studies
- Keywords
- proton g-factor, Penning trap, antiprotons, magnetic moment, Larmor frequency, magnetic bottle, spin-flip transitions, uniform magnetic field
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An experiment for the direct determination of the g-factor of a single proton in a Penning trap. https://app.cochat.ai/papers/10.1088/1367-2630/14/6/063011
- The paper
- Rodegheri, C. C., Blaum, K., Kracke, H., Kreim, S., Mooser, A., Quint, W., Ulmer, S., & Walz, J. (2012). An experiment for the direct determination of the g-factor of a single proton in a Penning trap. New Journal of Physics. https://doi.org/10.1088/1367-2630/14/6/063011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.