CoChat

Lamb shifts and hyperfine structure inLi+6andLi+7: Theory and experiment

Open access
Riis, E., Sinclair, A. G., Poulsen, O., Drake, G. W. F., Rowley, W. R. C., Levick, A. P. · 1994 · Physical Review A
Cited by 125

The DOI matches its Crossref record.

Abstract

High-precision laser-resonance measurements accurate to \ifmmode\pm\else\textpm\fi{}0.5 MHz or better are reported for transitions among the 1s2s $^{3}$${\mathit{S}}_{1--}$1s2p $^{3}$${\mathit{P}}_{\mathit{J}}$ hyperfine manifolds for each of J=0, 1, and 2 in both $^{6}\mathrm{Li}^{+}$ and $^{7}\mathrm{Li}^{+}$. A detailed analysis of hyperfine structure is performed for both the S and P states, using newly calculated values for the magnetic dipole and electric quadrupole coupling constants, and the hyperfine shifts subtracted from the measurements. The resulting transition frequencies are then analyzed on three different levels. First, the isotope shifts in the fine-structure splittings are calculated from the relativistic reduced mass and recoil terms in the Breit interaction, and compared with experiment at the \ifmmode\pm\else\textpm\fi{}0.5-MHz level of accuracy. This comparison is particularly significant because J-independent theoretical uncertainties reduce through cancellation to the \ifmmode\pm\else\textpm\fi{}0.01-MHz level. Second, the isotope shifts in the full transition frequencies are used to deduce the difference in rms nuclear radii.The result is ${\mathit{R}}_{\mathrm{rms}}$${(}^{6}$Li)-${\mathit{R}}_{\mathrm{rms}}$${(}^{7}$Li)=0.15\ifmmode\pm\else\textpm\fi{}0.01 fm, in agreement with nuclear scattering data, but with substantially improved accuracy. Third, high-precision calculations of the low-order non-QED contributions to the transition frequencies are subtracted from the measurements to obtain the residual QED shifts. The isotope-averaged and spin-averaged effective shift for $^{7}\mathrm{Li}^{+}$ is 37 429.40\ifmmode\pm\else\textpm\fi{}0.39 MHz, with an additional uncertainty of \ifmmode\pm\else\textpm\fi{}1.5 MHz due to finite nuclear size corrections. The accuracy of 11 parts per million is the best two-electron Lamb shift measurement in the literature, and is comparable to the accuracies achieved in hydrogen. Theoretical contributions to the two-electron Lamb shift are discussed, including terms of order (\ensuremath{\alpha}Z${)}^{4}$ recently obtained by Chen, Cheng, and Johnson [Phys. Rev. A 47, 3692 (1993)], and the results used to extract a QED shift for the 2 $^{3}$${\mathit{S}}_{1}$ state. The result of 30 254\ifmmode\pm\else\textpm\fi{}12 MHz is shown to be in good accord with theory (30 250\ifmmode\pm\else\textpm\fi{}30 MHz) when two-electron corrections to the Bethe logarithm are taken into account by a 1/Z expansion method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.49.207

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Riis, E., Sinclair, A. G., Poulsen, O., Drake, G. W. F., Rowley, W. R. C., & Levick, A. P.
Venue
Physical Review A
Published
1994-01-01
Volume
49
Issue
1
Pages
207-220
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W2094619075
Cited by
125
References
0
FWCI
5.13
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.