Isotope-selective photoionization for calcium ion trapping
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
We present studies of resonance-enhanced photoionization for isotope-selective loading of ${\mathrm{Ca}}^{+}$ into a Paul trap. The ${4s}^{2}{}^{1}{S}_{0}\ensuremath{\leftrightarrow}4s4p{}^{1}{P}_{1}$ transition of neutral calcium is driven by a 423 nm laser and the atoms are photoionized by a second laser at 389 nm. Isotope selectivity is achieved by using crossed atomic and laser beams to reduce the Doppler width significantly below the isotope shifts in the 423 nm transition. The loading rate of ions into the trap is studied under a range of experimental parameters for the abundant isotope ${}^{40}{\mathrm{Ca}}^{+}.$ Using the fluorescence of the atomic beam at 423 nm as a measure of the Ca number density, we estimate a lower limit for the absolute photoionization cross section of 170(60) Mb. We achieve loading and laser cooling of all the naturally occurring isotopes, without the need for enriched sources. Laser heating/cooling is observed to enhance the isotope selectivity. In the case of the rare species ${}^{43}{\mathrm{Ca}}^{+}$ and ${}^{46}{\mathrm{Ca}}^{+},$ which have not previously been laser cooled, the loading is not fully isotope selective, but we show that pure crystals of ${}^{43}{\mathrm{Ca}}^{+}$ may nevertheless be obtained. We find that for loading ${}^{40}{\mathrm{Ca}}^{+}$ the 389 nm laser may be replaced by an incoherent source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Theory of Atomic Structure and Spectra
Cowan, R. D. (1981) · University of California Press eBooks · doi:10.1525/9780520906150 · Cited by 5,186
Thermochemical data of pure substances
(1993) · Choice Reviews Online · doi:10.5860/choice.31-0632 · Cited by 4,494
Atomic and Molecular Beam Methods
Scoles, G. (1988) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,262
Architecture for a large-scale ion-trap quantum computer
Kielpinski, D., Monroe, C., & Wineland, D. J. (2002) · Nature · doi:10.1038/nature00784 · Cited by 1,589
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Heating of trapped ions from the quantum ground state
Turchette, Q. A., Kielpinski, King, B. E., Leibfried, D., Meekhof, D. M., Myatt, C. J., Rowe, M. A., Sackett, C. A., Wood, C. S., Itano, W. M., et al. (2000) · Physical Review A · doi:10.1103/physreva.61.063418 · Cited by 544
A scalable quantum computer with ions in an array of microtraps
Cirac, J. I., & Zoller, P. (2000) · Nature · doi:10.1038/35007021 · Cited by 516
Isotope-abundance variations of selected elements (IUPAC Technical Report)
Coplen, T. B., Böhlke, J. K., De Bièvre, P., Ding, T., Holden, N. E., Hopple, J. A., Krouse, H. R., Lamberty, A., Peiser, H. S., Revesz, K., et al. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274101987 · Cited by 437
The ion trap quantum information processor
Steane, A. (1997) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050225 · Cited by 321
Self-citationThe coherence of qubits based on single Ca ions
Schmidt-Kaler, F., Gulde, S., Riebe, M., Deuschle, T., Kreuter, A., Lancaster, G., Becher, C., Eschner, J., H ffner, H., & Blatt, R. (2003) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/36/3/319 · Cited by 154
Transport of quantum states and separation of ions in a dual RF ion trap
Rowe, M. A., Ben-Kish, A., DeMarco, B., Leibfried, D., Meyer, V., Beall, J., Britton, J., Hughes, J., Itano, W. M., Jelenkovic, B., et al. (2002) · Quantum Information and Computation · doi:10.26421/qic2.4-1 · Cited by 138
Isotope selective loading of an ion trap using resonance-enhanced two-photon ionization
Kjærgaard, N., Hornekær, L., Thommesen, A. M., Videsen, Z., & Drewsen, M. (2000) · Applied Physics B · doi:10.1007/s003400000296 · Cited by 133
Measurement of the lifetime of the3d2D5/2state in40Ca+
Barton, P. A., Donald, C. J. S., Lucas, D. M., Stevens, D. A., Steane, A. M., & Stacey, D. N. (2000) · Physical Review A · doi:10.1103/physreva.62.032503 · Cited by 132
Self-citationSimple and efficient photo-ionization loading of ions for precision ion-trapping experiments
Gulde, S., Rotter, D., Barton, P., Schmidt‐Kaler, F., Blatt, R., & Hogervorst, W. (2001) · Applied Physics B · doi:10.1007/s003400100749 · Cited by 128
Sympathetic cooling of trappedCd+isotopes
Blinov, B. B., Deslauriers, L., Lee, P., Madsen, M. J., Miller, R., & Monroe, C. (2002) · Physical Review A · doi:10.1103/physreva.65.040304 · Cited by 97
Sympathetic Crystallization of Trapped Ions
Bowe, P. D., Hornekær, L., Brodersen, C., Drewsen, M., Hangst, J. S., & Schiffer, J. P. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.2071 · Cited by 86
The “Trapped State” of a Trapped Ion—Line Shifts and Shape
Siemers, I., Schubert, M., Blatt, R., Neuhauser, W., & Toschek, P. E. (1992) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/18/2/009 · Cited by 70
Boshier, M. G., Barwood, G. P., Huang, G., & Klein, H. A. (2000) · Applied Physics B · doi:10.1007/s003400050074 · Cited by 30
Deterministic coupling of single ions to an optical cavity
Keller, M., Lange, B., Hayasaka, K., Lange, W., & Walther, H. (2003) · Applied Physics B · doi:10.1007/s00340-003-1114-x · Cited by 30
Coherent coupling of a single 40 Ca + ion to a high-finesse optical cavity
Mundt, A. B., Kreuter, A., Russo, C., Becher, C., Leibfried, D. G., Eschner, J., Schmidt‐Kaler, F., & Blatt, R. (2003) · Applied Physics B · doi:10.1007/s00340-002-1073-7 · Cited by 30
Oxford ion-trap quantum computing project
Lucas, D. M., Donald, C. J. S., Home, J., McDonnell, M. J., Ramos, A. Y., Stacey, D. N., Stacey, J.-P., Steane, A. M., & Webster, S. C. (2003) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2003.1209 · Cited by 22
Self-citationPrecision Nuclear Measurements with Ion Traps
Savard, G., & Werth, G. (2000) · Annual Review of Nuclear and Particle Science · doi:10.1146/annurev.nucl.50.1.119 · Cited by 21
Isotope separation by nonlinear resonances in a Paul trap
Alheit, R., Enders, K., & Werth, G. (1996) · Applied Physics B · doi:10.1007/bf01081052 · Cited by 20
Cited by
High-Fidelity Quantum Logic Gates Using Trapped-Ion Hyperfine Qubits
Ballance, C. J., Harty, T. P., Linke, N. M., Sepiol, M. A., & Lucas, D. M. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.060504 · Cited by 777
Self-citationHigh-Fidelity Preparation, Gates, Memory, and Readout of a Trapped-Ion Quantum Bit
Harty, T. P., Allcock, D. T. C., Ballance, C. J., Guidoni, L., Janacek, H. A., Linke, N. M., Stacey, D. N., & Lucas, D. M. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.220501 · Cited by 632
Self-citationIntegrated optical multi-ion quantum logic
Mehta, K. K., Zhang, C., Malinowski, M., Nguyen, T.-L., Stadler, M., & Home, J. P. (2020) · Nature · doi:10.1038/s41586-020-2823-6 · Cited by 318
Self-citationHigh Fidelity State Preparation and Measurement of Ion Hyperfine Qubits with I>12
An, F. A., Ransford, A., Schaffer, A., Sletten, L. R., Gaebler, J., Hostetter, J., & Vittorini, G. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.130501 · Cited by 59
Heating rates and ion-motion control in a Y -junction surface-electrode trap
Shu, G., Vittorini, G., Buikema, A., Nichols, C. S., Volin, C., Stick, D., & Brown, K. R. (2014) · Physical Review A · doi:10.1103/physreva.89.062308 · Cited by 58
Metadata
- Authors
- Lucas, D., Ramos, A., Home, J., McDonnell, M., Nakayama, S., Stacey, J.-P., Webster, S., Stacey, D., & Steane, A.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2004-01
- Volume
- 69
- Issue
- 1
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2091499951
- Cited by
- 162
- References
- 23
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.