Low-noise high-density alkali-metal scalar magnetometer
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present an experimental and theoretical study of a scalar atomic magnetometer using an oscillating field-driven Zeeman resonance in a high-density optically pumped potassium vapor. We describe an experimental implementation of an atomic gradiometer with a noise level below $10\text{ }\text{fT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, fractional field sensitivity below ${10}^{\ensuremath{-}9}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$, and an active measurement volume of about $1.5\text{ }{\text{cm}}^{3}$. We show that the fundamental field sensitivity of a scalar magnetometer is determined by the rate of alkali-metal spin-exchange collisions even though the resonance linewidth can be made much smaller than the spin-exchange rate by pumping most atoms into a stretched spin state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citation
Cited by
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Self-citationUltra-low-loss integrated visible photonics using thin-film lithium niobate
Desiatov, B., Shams-Ansari, A., Zhang, M., Wang, C., & Lončar, M. (2019) · Optica · doi:10.1364/optica.6.000380 · Cited by 332
Kitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
Magnetic Sensitivity Beyond the Projection Noise Limit by Spin Squeezing
Sewell, R. J., Koschorreck, M., Napolitano, M., Dubost, B., Behbood, N., & Mitchell, M. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.253605 · Cited by 323
Metadata
- Authors
- Smullin, S. J., Savukov, I. M., Vasilakis, G., Ghosh, R. K., & Romalis, M. V.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2009-09-29
- Volume
- 80
- Issue
- 3
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1967274937
- Cited by
- 139
- References
- 2
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-noise high-density alkali-metal scalar magnetometer. https://app.cochat.ai/papers/10.1103/physreva.80.033420
- The paper
- Smullin, S. J., Savukov, I. M., Vasilakis, G., Ghosh, R. K., & Romalis, M. V. (2009). Low-noise high-density alkali-metal scalar magnetometer. Physical Review A. https://doi.org/10.1103/physreva.80.033420
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.