Stray-field-induced quadrupole shift and absolute frequency of the 688-THzY171b+single-ion optical frequency standard
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We report experimental investigations of a single-ion optical frequency standard based on ${^{171}\text{Y}\text{b}}^{+}$. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the ${^{2}S}_{1/2}(F=0)--{^{2}D}_{3/2}({F}^{\ensuremath{'}}=2)$ electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the ${^{2}D}_{3/2}$ state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as $688\text{ }358\text{ }979\text{ }309\text{ }306.62\ifmmode\pm\else\textpm\fi{}0.73\text{ }\text{Hz}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Single-Ion Nuclear Clock for Metrology at the 19th Decimal Place
Campbell, C. J., Radnaev, A. G., Kuzmich, A., Dzuba, V. A., Flambaum, V. V., & Derevianko, A. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.120802 · Cited by 347
Metadata
- Authors
- Tamm, C., Weyers, S., Lipphardt, B., & Peik, E.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2009-10-06
- Volume
- 80
- Issue
- 4
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1985249291
- Cited by
- 103
- References
- 1
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.