The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Open accessAbstract
Two coherent frequency combs are used to measure the full complex response of a sample in a configuration analogous to a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual-comb spectrometer retains the frequency accuracy and resolution of the reference underlying the stabilized combs. We discuss the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the overtone vibration of hydrogen cyanide, centered at THz ( nm). We measure the fully normalized, complex response of the gas over a THz bandwidth at MHz frequency resolution yielding resolution elements. The average spectral signal-to-noise ratio (SNR) over the THz bandwidth is for both the magnitude and phase of the measured spectral response and the peak SNR is . This peak SNR corresponds to a fractional absorption sensitivity of and a phase sensitivity of microradians. As the spectral coverage of combs expands, coherent dual-comb spectroscopy could provide high-frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions. Work of U. S. government, not subject to copyright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The widths of the calculated absorption lines are 0.90, 0.85, and 0.91 GHz, respectively.”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [28]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The measured spectra and the database show good agreement in terms of both the absorption intensity and linewidth.”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [28]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supercontinuum generation in photonic crystal fiber
Dudley, J. M., Genty, G., & Coen, S. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1135 · Cited by 4,337
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B · doi:10.1007/bf00702605 · Cited by 3,821
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationTwo-Dimensional Femtosecond Spectroscopy
Jonas, D. M. (2003) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.54.011002.103907 · Cited by 1,198
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Self-citationLepetit, L., Chériaux, G., & Joffre, M. (1995) · Journal of the Optical Society of America B · doi:10.1364/josab.12.002467 · Cited by 967
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 913
Multidimensional Femtosecond Correlation Spectroscopies of Electronic and Vibrational Excitations
Mukamel, S. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.691 · Cited by 894
Research works printed but not linked: 2
- P. Jacquet, 2009, Fourier transform spectroscopy
- 1964, Handbook of Mathematical Functions with Formulas, Graphs, and Mathematical Tables
Cited by
Sorted by citations
Items 301–321 of 321
Measurement of absorption spectroscopy enabled by a polarization-multiplexed dual-comb laser
Zhang, C., Wang, G., Sun, J., Fu, B., & Xu, L. (2023) · IEEE International Conference on Imaging Systems and Techniques (IST) · doi:10.1109/ist59124.2023.10355701
Gómez, R. J. M., Gómez, P. M. M., & Antonio, D. (2024) · Nanotechnology Perceptions · doi:10.62441/nano-ntp.v20i2.3
Chatterjee, D., Bancel, E.-L., Conforti, M., Sivankutty, S., Rigneault, H., Szriftgiser, P., Cundiff, S. T., & Mussot, A. (2024) · doi:10.1364/opticaopen.26396656.v1
Advancing Molecular Spectroscopy Efficiency with Extensive Parallelism
Li, J., Fernandez, R. N., Gutierrez, B., Pedersen, J. B., & Zhou, Y. (2024) · Metrology · doi:10.3390/metrology4040043
Selection of wavelength bands for ultra-long open-path dual-comb spectroscopy
Zhong, W., Xue, X., Tian, P., & Wu, J. (2025) · JUSTC · doi:10.52396/justc-2024-0127
Real-time electro-optic dual comb detection of ultrasound waves
Chatterjee, D., Etien, L., Boivinet, S., Rigneault, H., Chaigne, T., & Mussot, A. (2025) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/adeeed
Phononic frequency combs in twisted bilayer van der Waals material resonators
Liu, R., & Zhu, G. (2025) · Journal of Applied Physics · doi:10.1063/5.0296669
Yue, 李. L., Bo, 孙. S., Zhijian, 高. G., Yingjie, 刘. L., & Mingjiang, 张. Z. (2025) · Acta Optica Sinica (Online) · doi:10.3788/aosol250516
Optical Microscopy Using Optical-Frequency-Comb
MINAMIKAWA, T. (2024) · The Review of Laser Engineering · doi:10.2184/lsj.52.7_326
Compact Environmentally-Stable Figure-9 Fiber Laser with Large Repetition Rate Tuning Ranges
Zhu, R., Liang, H., Qiu, Z., Zhou, Z., Wu, G., & Chen, J. (2025) · Asia Communications and Photonics Conference · doi:10.1109/acp66871.2025.11350607
Liao, Y., Hu, M., ZHANG, H., Zhao, Y., Lv, J., & Wang, Q. (2026) · Photonics Research · doi:10.1364/prj.585494
Development of a dual comb laser source toward atmospheric radical OH monitoring
Pivard, C. (2021) · theses.fr (ABES) · doi:10.70675/115ffd45z40dfz4c0aza86eze58f5ada5e26
Xiong, Y., Jiaqi, 周. Z., & Yan, 冯. F. (2026) · Chinese Journal of Lasers · doi:10.3788/cjl260501
Spectroscopic Methane (CH 4 ) Sensing Methods and Recent Progress: A Review
Santini, L., Coelho, L., & Floridia, C. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3701488
Lucia, F. D., Sun, Y., Dupont, C., Englebert, N., Semaan, G., Gorza, S.-P., & Leo, F. (2026) · doi:10.1364/cleo_si.2026.sth2i.4
Performance studies of wavelength-multiplexed single-cavity dual combs based on Lyot filter
Pu, Y., Zhang, Y., Wu, Z., Zhang, Y., Shu, C., Yan, C., & Ye, J. (2026) · Laser Physics · doi:10.1088/1555-6611/ae8504
Zhao, K., Zhou, S., Hu, Y., & Gao, C. (2026) · Applied Optics · doi:10.1364/ao.610354
Reconfigurable Terahertz Multi‐Harmonic Dual‐Combs
Ma, X., Qin, Z., Bi, X., Li, Z., Wan, W., Liu, B., Liu, G., Pan, Y., Lu, Y., & Li, H. (2026) · Nanophotonics · doi:10.1002/nap2.70281
Metadata
- Authors
- Coddington, I., Swann, W., & Newbury, N.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2010-10-12
- Volume
- 82
- Issue
- 4
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1998377056
- Cited by
- 322
- References
- 67
- Citations by year
- 2026: 8 · 2025: 20 · 2024: 24 · 2023: 32 · 2022: 16 · 2021: 23 · 2020: 16 · 2019: 22 · 2018: 38 · 2017: 17 · 2016: 33 · 2015: 20 · 2014: 20 · 2013: 8 · 2012: 11
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Physical Review A (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- frequency combs, signal-to-noise ratio, hydrogen cyanide, overtone vibrations, terahertz spectroscopy, phase sensitivity, absorption sensitivity, high frequency resolution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review