The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Open accessAbstract
Two coherent frequency combs are used to measure the full complex response of a sample in a configuration analogous to a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual-comb spectrometer retains the frequency accuracy and resolution of the reference underlying the stabilized combs. We discuss the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the overtone vibration of hydrogen cyanide, centered at THz ( nm). We measure the fully normalized, complex response of the gas over a THz bandwidth at MHz frequency resolution yielding resolution elements. The average spectral signal-to-noise ratio (SNR) over the THz bandwidth is for both the magnitude and phase of the measured spectral response and the peak SNR is . This peak SNR corresponds to a fractional absorption sensitivity of and a phase sensitivity of microradians. As the spectral coverage of combs expands, coherent dual-comb spectroscopy could provide high-frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions. Work of U. S. government, not subject to copyright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The widths of the calculated absorption lines are 0.90, 0.85, and 0.91 GHz, respectively.”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [28]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The measured spectra and the database show good agreement in terms of both the absorption intensity and linewidth.”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [28]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supercontinuum generation in photonic crystal fiber
Dudley, J. M., Genty, G., & Coen, S. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1135 · Cited by 4,337
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B · doi:10.1007/bf00702605 · Cited by 3,821
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationTwo-Dimensional Femtosecond Spectroscopy
Jonas, D. M. (2003) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.54.011002.103907 · Cited by 1,198
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Self-citationLepetit, L., Chériaux, G., & Joffre, M. (1995) · Journal of the Optical Society of America B · doi:10.1364/josab.12.002467 · Cited by 967
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 913
Multidimensional Femtosecond Correlation Spectroscopies of Electronic and Vibrational Excitations
Mukamel, S. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.691 · Cited by 894
Coherent Multiheterodyne Spectroscopy Using Stabilized Optical Frequency Combs
Coddington, I. R., Swann, W. C., & Newbury, N. R. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.013902 · Cited by 821
Self-citationMolecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L. W., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 799
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 630
Introductory Fourier Transform Spectroscopy
Bell, R. J. (1972) · Elsevier eBooks · doi:10.1016/b978-0-12-085150-8.x5001-3 · Cited by 613
Cavity-enhanced dual-comb spectroscopy
Bernhardt, B., Ozawa, A., Jacquet, P., Jacquey, M., Kobayashi, Y., Udem, T., Holzwarth, R., Guelachvili, G., Hänsch, T. W., & Picqué, N. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.217 · Cited by 589
Broadband Cavity Ringdown Spectroscopy for Sensitive and Rapid Molecular Detection
Thorpe, M. J., Moll, K. D., Jones, R. J., Safdi, B. R., & Ye, J. (2006) · Science · doi:10.1126/science.1123921 · Cited by 510
Ultrafast time-domain spectroscopy based on high-speed asynchronous optical sampling
Bartels, A., Cerna, R., Kistner, C., Thoma, A., Hudert, F., Janke, C., & Dekorsy, T. (2007) · Review of Scientific Instruments · doi:10.1063/1.2714048 · Cited by 460
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Fundamental Noise Limitations to Supercontinuum Generation in Microstructure Fiber
Corwin, K. L., Newbury, N. R., Dudley, J. M., Coen, S., Diddams, S. A., Weber, K., & Windeler, R. S. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.113904 · Cited by 404
Self-citationStretched-pulse additive pulse mode-locking in fiber ring lasers: theory and experiment
Haus, H. A., Tamura, K. R., Nelson, L. E., & Ippen, E. P. (1995) · IEEE Journal of Quantum Electronics · doi:10.1109/3.364417 · Cited by 400
Frequency-comb infrared spectrometer for rapid, remote chemical sensing
Schließer, A., Brehm, M., Keilmann, F., & van der Weide, D. W. (2005) · Optics Express · doi:10.1364/opex.13.009029 · Cited by 383
Fourier transform spectroscopy with a laser frequency comb
Mandon, J., Guelachvili, G., & Picqué, N. (2009) · Nature Photonics · doi:10.1038/nphoton.2008.293 · Cited by 349
Fourier Transform Spectrometry
(2001) · Elsevier eBooks · doi:10.1016/b978-0-12-042510-5.x5000-8 · Cited by 344
Photo Echo and Optical Nutation in Molecules
Brewer, R. G., & Shoemaker, R. L. (1971) · Physical Review Letters · doi:10.1103/physrevlett.27.631 · Cited by 338
Demtröder, W. (1996) · Springer eBooks · doi:10.1007/978-3-662-08260-7 · Cited by 331
Phase-stabilized, 15 W frequency comb at 28–48 μm
Adler, F., Cossel, K. C., Thorpe, M. J., Hartl, I., Fermann, M. E., & Ye, J. (2009) · Optics Letters · doi:10.1364/ol.34.001330 · Cited by 315
Brewer, R. G., & Shoemaker, R. L. (1972) · Physical Review A · doi:10.1103/physreva.6.2001 · Cited by 312
Low-noise fiber-laser frequency combs (Invited)
Newbury, N. R., & Swann, W. C. (2007) · Journal of the Optical Society of America B · doi:10.1364/josab.24.001756 · Cited by 302
Self-citationSensitivity of coherent dual-comb spectroscopy
Newbury, N. R., Coddington, I. R., & Swann, W. C. (2010) · Optics Express · doi:10.1364/oe.18.007929 · Cited by 278
Self-citationFelker, P. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100199a005 · Cited by 260
Femtosecond wave packet spectroscopy: Coherences, the potential, and structural determination
Gruebele, M., & Zewail, A. H. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464253 · Cited by 249
Cavity-Enhanced Direct Frequency Comb Spectroscopy: Technology and Applications
Adler, F., Thorpe, M. J., Cossel, K. C., & Ye, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155248 · Cited by 244
Direct frequency comb synthesis with arbitrary offset and shot-noise-limited phase noise
Koke, S., Grebing, C., Frei, H., Anderson, A., Assion, A., & Steinmeyer, G. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.91 · Cited by 241
Yasui, T., Kabetani, Y., Saneyoshi, E., Yokoyama, S., & Araki, T. (2006) · Applied Physics Letters · doi:10.1063/1.2209718 · Cited by 223
Cavity-enhanced direct frequency comb spectroscopy
Thorpe, M. J., & Ye, J. (2008) · Applied Physics B · doi:10.1007/s00340-008-3019-1 · Cited by 199
Soliton versus nonsoliton operation of fiber ring lasers
Tamura, K. R., Nelson, L. E., Haus, H. A., & Ippen, E. P. (1994) · Applied Physics Letters · doi:10.1063/1.111547 · Cited by 194
Elzinga, P. A., Kneisler, R. J., Lytle, F. E., Jiang, Y., King, G. B., & Laurendeau, N. M. (1987) · Applied Optics · doi:10.1364/ao.26.004303 · Cited by 194
Gohle, C., Stein, B., Schließer, A., Udem, T., & Hänsch, T. W. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.263902 · Cited by 185
Ultralow-frequency-noise stabilization of a laser by locking to an optical fiber-delay line
Kéfélian, F., Jiang, H., Lemonde, P., & Santarelli, G. (2009) · Optics Letters · doi:10.1364/ol.34.000914 · Cited by 183
The Principles of Interferometric Spectroscopy
Viney, J. C. (1979) · Optica Acta International Journal of Optics · doi:10.1080/716099457 · Cited by 179
Fourier-transform spectroscopy
(2008) · International Union of Pure and Applied Chemistry (IUPAC) eBooks · doi:10.1351/goldbook.ft07382 · Cited by 144
Mode-locked fiber laser frequency-controlled with an intracavity electro-optic modulator
Hudson, D. D., Holman, K. W., Jones, R. J., Cundiff, S. T., Ye, J., & Jones, D. J. (2005) · Optics Letters · doi:10.1364/ol.30.002948 · Cited by 140
Introductory Fourier Transform Spectroscopy
Jerrard, H. G. (1973) · Physics Bulletin · doi:10.1088/0031-9112/24/2/018 · Cited by 139
Noise amplification during supercontinuum generation in microstructure fiber
Newbury, N. R., Washburn, B. R., Corwin, K. L., & Windeler, R. S. (2003) · Optics Letters · doi:10.1364/ol.28.000944 · Cited by 138
Self-citationSorokin, E., Sorokina, I. T., Mandon, J., Guelachvili, G., & Picqué, N. (2007) · Optics Express · doi:10.1364/oe.15.016540 · Cited by 132
Giaccari, P., Deschênes, J.-D., Saucier, P., Genest, J., & Tremblay, P. (2008) · Optics Express · doi:10.1364/oe.16.004347 · Cited by 128
THz commensurate echoes: Periodic rephasing of molecular transitions in free-induction decay
Harde, H., Keiding, S. R., & Grischkowsky, D. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.1834 · Cited by 123
Coherent linear optical sampling at 15 bits of resolution
Coddington, I., Swann, W. C., & Newbury, N. R. (2009) · Optics Letters · doi:10.1364/ol.34.002153 · Cited by 120
Self-citationHigh-performance, vibration-immune, fiber-laser frequency comb
Baumann, E., Giorgetta, F. R., Nicholson, J. W., Swann, W. C., Coddington, I. R., & Newbury, N. R. (2009) · Optics Letters · doi:10.1364/ol.34.000638 · Cited by 118
Self-citationCoddington, I. R., Swann, W. C., Lorini, L., Bergquist, J., Coq, Y. L., Oates, C. W., Quraishi, Q. S., Feder, K. S., Nicholson, J. W., Westbrook, P. S., et al. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.71 · Cited by 118
Self-citationFiber-laser frequency combs with subhertz relative linewidths
Swann, W. C., McFerran, J. J., Coddington, I. R., Newbury, N. R., Hartl, I., Fermann, M. E., Westbrook, P. S., Nicholson, J. W., Feder, K. S., Langrock, C., et al. (2006) · Optics Letters · doi:10.1364/ol.31.003046 · Cited by 115
Self-citationResponse dynamics of the frequency comb output from a femtosecond fiber laser
Washburn, B. R., Swann, W. C., & Newbury, N. R. (2005) · Optics Express · doi:10.1364/opex.13.010622 · Cited by 115
Self-citationSwann, W. C., & Gilbert, S. L. (2005) · Journal of the Optical Society of America B · doi:10.1364/josab.22.001749 · Cited by 105
Self-citationTheory of the frequency comb output from a femtosecond fiber laser
Newbury, N. R., & Washburn, B. R. (2005) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.2005.857657 · Cited by 104
Self-citationTime-domain spectroscopy of molecular free-induction decay in the infrared
Coddington, I. R., Swann, W. C., & Newbury, N. R. (2010) · Optics Letters · doi:10.1364/ol.35.001395 · Cited by 97
Self-citationRapid-scanning terahertz precision spectrometer with more than 6 THz spectral coverage
Klatt, G., Gebs, R., Janke, C., Dekorsy, T., & Bartels, A. (2009) · Optics Express · doi:10.1364/oe.17.022847 · Cited by 95
McFerran, J. J., Swann, W. C., Washburn, B. R., & Newbury, N. R. (2006) · Applied Physics B · doi:10.1007/s00340-006-2426-4 · Cited by 84
Self-citationSpectroscopic near-field microscopy using frequency combs in the mid-infrared
Brehm, M., Schließer, A., & Keilmann, F. (2006) · Optics Express · doi:10.1364/oe.14.011222 · Cited by 82
Mid-infrared fibre-based optical comb
Maddaloni, P., Malara, P., Gagliardi, G., & Natale, P. D. (2006) · New Journal of Physics · doi:10.1088/1367-2630/8/11/262 · Cited by 72
Dispersive Fourier transform spectroscopy
Birch, J. R. (1987) · Microchimica Acta · doi:10.1007/bf01201686 · Cited by 54
Femtosecond laser Fourier transform absorption spectroscopy
Mandon, J., Guelachvili, G., Picqué, N., Druon, F., & Georges, P. (2007) · Optics Letters · doi:10.1364/ol.32.001677 · Cited by 51
Orphal, J., & Ruth, A. A. (2008) · Optics Express · doi:10.1364/oe.16.019232 · Cited by 49
Molecular Structure and Orientation: Concepts from Femtosecond Dynamics
Baskin, J. S., & Zewail, A. H. (2001) · The Journal of Physical Chemistry A · doi:10.1021/jp004525p · Cited by 47
Tillman, K. A., Maier, R. R. J., Reid, D. T., & McNaghten, E. D. (2005) · Journal of Optics A Pure and Applied Optics · doi:10.1088/1464-4258/7/6/023 · Cited by 33
Dorrer, C., Belabas, N., Likforman, J.-P., & Joffre, M. (2000) · Applied Physics B · doi:10.1007/s003400000333 · Cited by 33
Al-Moayed, N., & Afsar, M. N. (2006) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2006.876406 · Cited by 22
Research works printed but not linked: 2
- P. Jacquet, 2009, Fourier transform spectroscopy
- 1964, Handbook of Mathematical Functions with Formulas, Graphs, and Mathematical Tables
Cited by
Sorted by citations
Hodgkinson, J., & Tatam, R. P. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,759
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
Self-citationUltralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 576
Dual-comb spectroscopy based on quantum-cascade-laser frequency combs
Villares, G., Hugi, A., Blaser, S., & Faist, J. (2014) · Nature Communications · doi:10.1038/ncomms6192 · Cited by 535
On-chip dual-comb source for spectroscopy
Dutt, A., Joshi, C., Ji, X., Cardenas, J., Okawachi, Y., Luke, K., Gaeta, A. L., & Lipson, M. (2018) · Science Advances · doi:10.1126/sciadv.1701858 · Cited by 453
Metadata
- Authors
- Coddington, I., Swann, W., & Newbury, N.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2010-10-12
- Volume
- 82
- Issue
- 4
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1998377056
- Cited by
- 322
- References
- 67
- Citations by year
- 2026: 8 · 2025: 20 · 2024: 24 · 2023: 32 · 2022: 16 · 2021: 23 · 2020: 16 · 2019: 22 · 2018: 38 · 2017: 17 · 2016: 33 · 2015: 20 · 2014: 20 · 2013: 8 · 2012: 11
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Physical Review A (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- frequency combs, signal-to-noise ratio, hydrogen cyanide, overtone vibrations, terahertz spectroscopy, phase sensitivity, absorption sensitivity, high frequency resolution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review