Enhancement of the phase-measurement sensitivity beyond the standard quantum limit by a nonlinear interferometer
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Quantum limits on noise in linear amplifiers
Caves, C. M. (1982) · Physical Review D · doi:10.1103/physrevd.26.1817 · Cited by 1,718
On the relative motion of the Earth and the luminiferous ether
Michelson, A. A., & Morley, E. W. (1887) · American Journal of Science · doi:10.2475/ajs.s3-34.203.333 · Cited by 1,507
Optics and interferometry with atoms and molecules
Cronin, A. D., Schmiedmayer, J., & Pritchard, D. E. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1051 · Cited by 1,420
SU(2) and SU(1,1) interferometers
Yurke, B., McCall, S. L., & Klauder, J. R. (1986) · Physical Review A · doi:10.1103/physreva.33.4033 · Cited by 1,366
Nonlinear atom interferometer surpasses classical precision limit
Gross, C., Zibold, T., Nicklas, E., Estève, J., & Oberthaler, M. K. (2010) · Nature · doi:10.1038/nature08919 · Cited by 949
Demonstration of the Einstein-Podolsky-Rosen paradox using nondegenerate parametric amplification
Reid, M. D. (1989) · Physical Review A · doi:10.1103/physreva.40.913 · Cited by 850
Precision measurement beyond the shot-noise limit
Xiao, M., Wu, L.-A., & Kimble, H. J. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.278 · Cited by 723
Kimble, H. J., Levin, Y., Matsko, A. B., Thorne, K. S., & Vyatchanin, S. P. (2001) · Physical Review D · doi:10.1103/physrevd.65.022002 · Cited by 667
Quantum-mechanical lossless beam splitter: SU(2) symmetry and photon statistics
Campos, R. A., Saleh, B. E. A., & Teich, M. C. (1989) · Physical Review A · doi:10.1103/physreva.40.1371 · Cited by 633
Cited by
Quantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
Quantum metrology with parametric amplifier-based photon correlation interferometers
Hudelist, F., Kong, J., Liu, C., Jing, J., Ou, Z. Y., & Zhang, W. (2014) · Nature Communications · doi:10.1038/ncomms4049 · Cited by 437
Self-citationPolino, E., Valeri, M., Spagnolo, N., & Sciarrino, F. (2020) · AVS Quantum Science · doi:10.1116/5.0007577 · Cited by 414
Imaging with quantum states of light
Moreau, P.-A., Toninelli, E., Gregory, T., & Padgett, M. J. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0056-0 · Cited by 400
Nonlinear interferometers in quantum optics
Chekhova, M. V., & Ou, Z. Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000104 · Cited by 287
Self-citationEffect of losses on the performance of an SU(1,1) interferometer
Marino, A. M., Corzo Trejo, N. V., & Lett, P. D. (2012) · Physical Review A · doi:10.1103/physreva.86.023844 · Cited by 179
Detection Loss Tolerant Supersensitive Phase Measurement with an SU(1,1) Interferometer
Manceau, M., Leuchs, G., Khalili, F., & Chekhova, M. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.223604 · Cited by 172
Metadata
- Authors
- Ou, Z. Y.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2012-02-14
- Volume
- 85
- Issue
- 2
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2325093831
- Cited by
- 195
- References
- 26
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.