Cavity-stabilized laser with acceleration sensitivity below10−12g−1
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We characterize the frequency sensitivity of a cavity-stabilized laser to inertial forces and temperature fluctuations, and perform real-time feedforward to correct for these sources of noise. We measure the sensitivity of the cavity to linear accelerations, rotational accelerations, and rotational velocities by rotating it about three axes with accelerometers and gyroscopes positioned around the cavity. The worst-direction linear acceleration sensitivity of the cavity is $2(1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}$ g${}^{\ensuremath{-}1}$ measured over 0--50 Hz, which is reduced by a factor of 50 to below ${10}^{\ensuremath{-}12}$ g${}^{\ensuremath{-}1}$ for low-frequency accelerations by real-time feedforward corrections of all of the aforementioned inertial forces. A similar idea is demonstrated in which laser frequency drift due to temperature fluctuations is reduced by a factor of 70 via real-time feedforward from a temperature sensor located on the outer wall of the cavity vacuum chamber.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Self-citationChou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Self-citationMa, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Bondarescu, R., Bondarescu, M., Hetényi, G., Boschi, L., Jetzer, P., & Balakrishna, J. (2012) · Geophysical Journal International · doi:10.1111/j.1365-246x.2012.05636.x · Cited by 71
Cited by
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Ultralow noise miniature external cavity semiconductor laser
Liang, W., Ilchenko, V. S., Eliyahu, D., Savchenkov, A. A., Matsko, A. B., Seidel, D., & Maleki, L. (2015) · Nature Communications · doi:10.1038/ncomms8371 · Cited by 398
Operation of an optically coherent frequency comb outside the metrology lab
Sinclair, L. C., Coddington, I., Swann, W. C., Rieker, G. B., Hati, A., Iwakuni, K., & Newbury, N. R. (2014) · Optics Express · doi:10.1364/oe.22.006996 · Cited by 211
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
Chip-based laser with 1-hertz integrated linewidth
Guo, J., McLemore, C. A., Xiang, C., Lee, D., Wu, L., Jin, W., Kelleher, M., Jin, N., Mason, D., Chang, L., et al. (2022) · Science Advances · doi:10.1126/sciadv.abp9006 · Cited by 112
Transportable interrogation laser system with an instability of mod σy = 3 × 10−16
Häfner, S., Herbers, S., Vogt, S., Lisdat, C., & Sterr, U. (2020) · Optics Express · doi:10.1364/oe.390105 · Cited by 37
Metadata
- Authors
- Leibrandt, D. R., Bergquist, J. C., & Rosenband, T.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2013-02-21
- Volume
- 87
- Issue
- 2
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2027949217
- Cited by
- 59
- References
- 6
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.