The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Optical Clocks and Relativity
Abstract
Relativity Comes Down to Earth: Over a century ago, Einstein presented the theory of relativity—where space and time are no longer fixed concepts, but are relative to an observer and their frame of reference. Tests of relativity have usually been confined to space-based measurements and/or with objects with velocities approaching the speed of light. Time-dilation and length-contraction have been confirmed and are used in satellite communication and global positioning systems. Using the precision of state-of-the-art optical clocks, Chou et al. (p. 1630 ) have confirmed that relativistic effects can now be measured at speeds attained by 100 meters sprinters (10 m/s) and gravitational effects due to just one meter height difference.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Chou et al. (2010) demonstrated the ability of the new generation of atomic clocks, based on optical transitions, to sense geoid height differences with a 30-cm level of accuracy.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Chou et al. (2010)
In the citing paper
“The potentiality of the new generation of atomic clocks has been shown in [64], based on optical transitions, to measure heights with a resolution of around 30 cm.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [64]
In the citing paper
“This gravitational redshift was confirmed for the Earth's field by Pound and Rebka [21]”
From Chapter 1 Theoretical background (1996) · cites this paper as [3]
In the citing paper
“Two clocks connected by a 75-m-long fibre delivered a height difference of 37 ± 15 cm. This finding agreed quite well with the known value of 33 cm (Chou et al. 2010).”
From Clock networks for height system unification: a simulation study (2019) · cites this paper as Chou et al. 2010
Citations
Cites
Zur Elektrodynamik bewegter Körper
Einstein, A. (1905) · Annalen der Physik · doi:10.1002/andp.19053221004 · Cited by 4,385
GRACE Measurements of Mass Variability in the Earth System
Tapley, B. D., Bettadpur, S., Ries, J. C., Thompson, P. F., & Watkins, M. M. (2004) · Science · doi:10.1126/science.1099192 · Cited by 2,555
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Self-citationPound, R. V., & Rebka, G. A. (1960) · Physical Review Letters · doi:10.1103/physrevlett.4.337 · Cited by 804
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationTest of Relativistic Gravitation with a Space-Borne Hydrogen Maser
Vessot, R. F. C., Levine, M. W., Mattison, E. M., Blomberg, E. L., Hoffman, T. E., Nystrom, G. U., Farrel, B. F., Decher, R., Eby, P. B., Baugher, C. R., et al. (1980) · Physical Review Letters · doi:10.1103/physrevlett.45.2081 · Cited by 649
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Self-citationQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Cited by
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
Theory and Experiment in Gravitational Physics
Will, C. M. (2018) · doi:10.1017/9781316338612 · Cited by 3,637
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Metadata
- Authors
- Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Chou, C. W.
- Venue
- Science
- Published
- 2010-09-24
- Volume
- 329
- Issue
- 5999
- Pages
- 1630-1633
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2009958141
- Cited by
- 828
- References
- 32
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 61 · 2023: 45 · 2022: 53 · 2021: 78 · 2020: 37 · 2019: 68 · 2018: 63 · 2017: 52 · 2016: 54 · 2015: 63 · 2014: 59 · 2013: 43 · 2012: 41
- FWCI
- 19.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical atomic clocks, time dilation, special relativity, general relativity, gravitational time dilation, clock synchronization, geodesy, fundamental physics tests
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Clocks and Relativity. https://app.cochat.ai/papers/10.1126/science.1192720
- The paper
- Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010). Optical Clocks and Relativity. Science. https://doi.org/10.1126/science.1192720
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.