Sensitivity limits of a Raman atom interferometer as a gravity gradiometer
Open accessThe DOI matches its Crossref record.
Abstract
We evaluate the sensitivity of a dual cloud atom interferometer to the measurement of vertical gravity gradient. We study the influence of most relevant experimental parameters on noise and long term drifts. Results are also applied to the case of doubly differential measurements of the gravitational signal from local source masses. We achieve a short-term sensitivity of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}$ g/$\sqrt{\text{Hz}}$ to differential gravity acceleration, limited by the quantum projection noise of the instrument. Active control of the most critical parameters allows us to reach a resolution of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}$ g after 8000 s on the measurement of differential gravity acceleration. The long-term stability is compatible with a measurement of the gravitational constant $G$ at the level of ${10}^{\ensuremath{-}4}$ after an integration time of about 100 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measurement of the fine-structure constant as a test of the Standard Model
Parker, R. H., Yu, C., Zhong, W., Estey, B., & Müller, H. (2018) · Science · doi:10.1126/science.aap7706 · Cited by 917
Precision measurement of the Newtonian gravitational constant using cold atoms
Rosi, G., Sorrentino, F., Cacciapuoti, L., Prevedelli, M., & Tino, G. M. (2014) · Nature · doi:10.1038/nature13433 · Cited by 739
Self-citationAEDGE: Atomic Experiment for Dark Matter and Gravity Exploration in Space
El-Neaj, Y. A., Alpigiani, C., Amairi-Pyka, S., Araújo, H., Balaž, A., Bassi, A., Bathe-Peters, L., Battelier, B., Belić, A., Bentine, E., et al. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-0080-0 · Cited by 348
Self-citationZhou, L., Long, S., Tang, B., Chen, X., Gao, F., Peng, W., Duan, W., Zhong, J., Xiong, Z., Wang, J., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.013004 · Cited by 282
Rosi, G., D’Amico, G., Cacciapuoti, L., Sorrentino, F., Prevedelli, M., Zych, M., Brukner, Č., & Tino, G. M. (2017) · Nature Communications · doi:10.1038/ncomms15529 · Cited by 217
Self-citation
Metadata
- Authors
- Sorrentino, F., Bodart, Q., Cacciapuoti, L., Lien, Y.-H., Prevedelli, M., Rosi, G., Salvi, L., & Tino, G. M.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2014-02-10
- Volume
- 89
- Issue
- 2
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W1971607380
- Cited by
- 228
- References
- 0
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity limits of a Raman atom interferometer as a gravity gradiometer. https://app.cochat.ai/papers/10.1103/physreva.89.023607
- The paper
- Sorrentino, F., Bodart, Q., Cacciapuoti, L., Lien, Y.-H., Prevedelli, M., Rosi, G., Salvi, L., & Tino, G. M. (2014). Sensitivity limits of a Raman atom interferometer as a gravity gradiometer. Physical Review A. https://doi.org/10.1103/physreva.89.023607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.