Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 410

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Comprehensive analysis of Si-dopedAlxGa1−xAs(x=0 to 1): Theory and experiments

Chand, Naresh, Henderson, Tim, Klem, John, Masselink, W. Ted, Fischer, Russ, Chang, Yia-Chung, Morkoĉ, Hadis · 1984 · Physical Review B

Abstract

Temperature-dependent Hall-effect measurements were carried out both in dark and in ambient light on Si-doped ${\mathrm{Al}}_{x}{\mathrm{Ga}}_{1\ensuremath{-}x}\mathrm{As}$ layers grown by molecular-beam epitaxy over the entire composition range. Above 150 K, the measured Hall carrier densities (different from actual electron densities near the direct-indirect transition) show an exponential dependence on temperature. A shallow donor (\ensuremath{\le}15 meV) tied to the $\ensuremath{\Gamma}$ band and a deep donor level tied to the $L$ band were observed. The deep donor is dominant for $x>0.2$, and its activation energy ${E}_{d}$ rises dramatically up to the direct-indirect band-gap crossover and peaks at 160 meV for $x\ensuremath{\sim}0.48$. As the A1 fraction increases further, ${E}_{d}$ decreases, reaching 57 meV for AlAs. The error due to multivalley conduction on the measured values of ${E}_{d}$ is shown to be negligible. The variation in ${E}_{d}$ of the dominant donor level with $x$ is accounted for by our theoretical calculations using a multivalley effective-mass model. A decrease of ${E}_{d}$ with increasing doping densities is also observed. At high substrate-growth temperature, the incorporation of Si atoms was found to decrease. The persistent-photoconductivity (PPC) effect was observed with an increase in mobilities over the dark values in the entire composition range. The effect was most pronounced in the range $0.20\ensuremath{\le}x\ensuremath{\le}0.40$. Traps related to the Si-doping density appear to be responsible for the observed photoconductivity effect. The ratio of the PCC traps and the Si atomic density is maximum at $x\ensuremath{\sim}0.32$ and is minimum in the direct-indirect band-gap crossover region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.30.4481

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 410

Metadata

Authors
Chand, N., Henderson, T., Klem, J., Masselink, W. T., Fischer, R., Chang, Y.-C., & Morkoĉ, H.
Venue
Physical Review B
Published
1984-10-15
Volume
30
Issue
8
Pages
4481-4492
ISSN
0163-1829 (ISSN-L)
OpenAlex
W2010350712
Cited by
410
References
5
FWCI
23.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.