Cited by 302Terahertz technology and applicationsSemiconductor materials and interfacesLaser-Matter Interactions and Applications

Carrier dynamics of electrons and holes in moderately doped silicon

Open access
van Exter, Martin, Grischkowsky, D.·1990·Physical Review B

Abstract

A time-domain spectroscopic technique, based on the generation and detection of a collimated beam of subpicosecond broadband terahertz pulses, is used to measure the absorption and dispersion of n- and p-type silicon, with resistivities of 0.1, 1, and 10 \ensuremath{\Omega} cm in the submillimeter range of 0.1--2 THz. From the transmission measurements performed at room temperature and at 80 K, the absorption and dispersion, and concomitantly the full complex conductivity, of the doped silicon could be obtained. The results provide an accurate view on the dynamics of the electrons and the holes. Although the simple Drude model, with an energy-independent relaxation time, gives a surprisingly accurate description of the observed carrier dynamics, the measurements do show that some refinements are needed. An extended model, with an energy-dependent carrier-relaxation rate, can explain most of the observed deviations from the simple Drude model.

Integrity signals

Registry

Crossref · 10.1103/physrevb.41.12140

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • High-resistivity silicon is a typical reference material for THz-TDS and a good starting point to test the method.

    “High-resistivity silicon is a typical reference material for THzTDS. Several historical studies have been published since the emergence of the THz-TDS field [4, 41, 16, 42], hence this type of sample is a good starting point to test our method.”

Cited by

Sorted by citations

Authors
van Exter, M., & Grischkowsky, D.
Affiliations
Cambridge Scientific (United States) (US)
Venue
Physical Review B
Published
1990-06-15
Volume
41
Issue
17
Pages
12140-12149
ISSN
  • 0163-1829 (ISSN-L)
  • 1095-3795
OpenAlex
W2026418275
Cited by
302
References
0
Citations by year
2026: 7 · 2025: 15 · 2024: 10 · 2023: 13 · 2022: 14 · 2021: 14 · 2020: 11 · 2019: 7 · 2018: 5 · 2017: 9 · 2016: 7 · 2015: 17 · 2014: 14 · 2013: 12 · 2012: 12
FWCI
5.74
Type
journal article
Language
en
Open access
Locations
  • Physical review. B, Condensed matter (publishedVersion)
  • PubMed (publishedVersion)
  • SHAREOK (University of Oklahoma; Oklahoma State University; Central Oklahoma University) (acceptedVersion, other-oa)
  • SHAREOK (University of Oklahoma; Oklahoma State University; Central Oklahoma University) (submittedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Semiconductor materials and interfaces
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
Keywords
carrier dynamics, doped silicon, terahertz spectroscopy, terahertz absorption, complex conductivity, Drude model, electron dynamics, hole dynamics, n-type silicon, p-type silicon, low-temperature transport

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review