The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Percolation exponents and thresholds obtained from the nearly ideal continuum percolation system graphite-boron nitride
Abstract
Compressed disks made from graphite and, its mechanical but not electrical isomorph, boron nitride as well as graphite-boron nitride powders, undergoing compression, are nearly ideal continuum percolation systems, as the ratio of their conductivities is nearly ${10}^{\ensuremath{-}18}$ and the scatter of the experimental points near the critical volume fraction ${\ensuremath{\varphi}}_{c}$ is very small. The following measurements, with the characteristic exponent(s) in brackets, are made on some or all of the samples in (axial) and at right angles (radial) to the direction of compression, as a function of the volume fraction of graphite (\ensuremath{\varphi}); dc conductivity ($s$ and $t$), dielectric constant ($s$), magnetoresistivity ${(t}_{\ensuremath{\perp}}),$ and noise power $(K).$ The noise power is also measured as function of resistance $(w)$ and volume ${(b}^{\ensuremath{'}}).$ The ${\ensuremath{\varphi}}_{c}$'s obtained for all measurements are consistent and explicable. The results for the exponents are less well understood but, where possible, these results are compared with theoretical predictions and previous experiments. The reasons for the nonuniversality of $t$ are clarified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kirkpatrick, S. (1973) · Reviews of Modern Physics · doi:10.1103/revmodphys.45.574 · Cited by 5,260
Cited by
Qin, F., & Brosseau, C. (2012) · Journal of Applied Physics · doi:10.1063/1.3688435 · Cited by 1,202
Electrical and thermal conductivity of polymers filled with metal powders
Mamunya, Y. P., Davydenko, V. V., Pissis, P., & Lebedev, E. V. (2002) · European Polymer Journal · doi:10.1016/s0014-3057(02)00064-2 · Cited by 1,029
Thermal Interface Materials: Historical Perspective, Status, and Future Directions
Prasher, R. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.879796 · Cited by 927
Nanoparticles functionalised with reversible molecular and supramolecular switches
Klajn, R., Stoddart, J. F., & Grzybowski, B. A. (2010) · Chemical Society Reviews · doi:10.1039/b920377j · Cited by 517
Heat and fluid flow in high-power LED packaging and applications
Luo, X., Hu, R., Liu, S., & Wang, K. (2016) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2016.05.003 · Cited by 460
Metadata
- Authors
- Wu, J., & McLachlan, D. S.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1997-07-15
- Volume
- 56
- Issue
- 3
- Pages
- 1236-1248
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W1999456562
- Cited by
- 223
- References
- 1
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percolation exponents and thresholds obtained from the nearly ideal continuum percolation system graphite-boron nitride. https://app.cochat.ai/papers/10.1103/physrevb.56.1236
- The paper
- Wu, J., & McLachlan, D. S. (1997). Percolation exponents and thresholds obtained from the nearly ideal continuum percolation system graphite-boron nitride. Physical Review B. https://doi.org/10.1103/physrevb.56.1236
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.