The DOI matches its Crossref record.
Factors Affecting the Height and Phase Images in Tapping Mode Atomic Force Microscopy. Study of Phase-Separated Polymer Blends of Poly(ethene-co-styrene) and Poly(2,6-dimethyl-1,4-phenylene oxide)
Abstract
Blends of two polymers, poly(ethene- co -styrene) (PES) and poly(2,6-dimethyl-1,4-phenylene oxide) (PPO), were examined with tapping mode atomic force microscopy (AFM) using various values of the driving amplitude A 0 and set-point amplitude ratio r sp = A sp / A 0, where A sp is the set-point amplitude. In height and phase images of PPO/PES blend samples, the relative contrast of chemically different regions depends sensitively on the r sp and A 0 values. As the tip−sample force is increased from small to large, both phase and height images of PPO/PES blend samples can undergo a contrast reversal twice. This makes it difficult to assign the features of height and phase images to different chemical components without performing additional experiments. Phase and height images were interpreted by analyzing several factors that affect the dependence of phase shift and amplitude damping on r sp and A 0 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solvent Vapor Annealing of Block Polymer Thin Films
Sinturel, C., Vayer, M., Morris, M., & Hillmyer, M. A. (2013) · Macromolecules · doi:10.1021/ma400735a · Cited by 543
Capillary forces in tapping mode atomic force microscopy
Zitzler, L., Herminghaus, S., & Mugele, F. (2002) · Physical Review B · doi:10.1103/physrevb.66.155436 · Cited by 305
Annealing-induced periodic patterns in solution grown polymer single crystals
Zhang, B., Chen, J., Zhang, H., Baier, M. C., Mecking, S., Reiter, R., Mülhaupt, R., & Reiter, G. (2015) · RSC Advances · doi:10.1039/c4ra10563j · Cited by 23
An in-situ hot stage for temperature-dependent tapping-mode™ atomic force microscopy
Prilliman, S. G., Kavanagh, A. M., Scher, E. C., Robertson, S. T., Hwang, K. S., & Colvin, V. L. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149090 · Cited by 19
Metadata
- Authors
- Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-07-01
- Volume
- 13
- Issue
- 14
- Pages
- 3807-3812
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2047434889
- Cited by
- 324
- References
- 0
- FWCI
- 12.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors Affecting the Height and Phase Images in Tapping Mode Atomic Force Microscopy. Study of Phase-Separated Polymer Blends of Poly(ethene-co-styrene) and Poly(2,6-dimethyl-1,4-phenylene oxide). https://app.cochat.ai/papers/10.1021/la970091m
- The paper
- Bar, G., Thomann, Y., Brandsch, R., Cantow, H.-J., & Whangbo, M.-H. (1997). Factors Affecting the Height and Phase Images in Tapping Mode Atomic Force Microscopy. Study of Phase-Separated Polymer Blends of Poly(ethene-co-styrene) and Poly(2,6-dimethyl-1,4-phenylene oxide). Langmuir. https://doi.org/10.1021/la970091m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.