Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 744

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Infrared Lattice Vibrations and Free-Electron Dispersion in GaN

Barker, A. S., Ilegems, M.·1973·Physical Review B

Abstract

Infrared reflectivity and absorption measurements have been made on single-crystal epitaxial GaN on (0001) $\ensuremath{\alpha}\ensuremath{-}$${\mathrm{Al}}_{2}$${\mathrm{O}}_{3}$ crystals. Analysis of the normal-incidence reflectance data on low-carrier-concentration layers using the Kramers-Kronig technique and dielectric oscillator fits yields the values ${\ensuremath{\omega}}_{\mathrm{TO}}^{\ensuremath{\perp}}=560$ ${\mathrm{cm}}^{\ensuremath{-}1}$ and ${\ensuremath{\omega}}_{\mathrm{LO}}^{\ensuremath{\perp}}=746$ ${\mathrm{cm}}^{\ensuremath{-}1}$ for the optical mode frequencies at 300 K. Adopting ${\ensuremath{\epsilon}}_{\ensuremath{\infty}}^{\ensuremath{\perp}}=5.35$ from a fit to Ejder's refractive-index data the additional quantities ${\ensuremath{\epsilon}}_{o}^{\ensuremath{\perp}}=9.5$ for the static dielectric constant, ${e}_{B}^{*\ensuremath{\perp}}=2.65e$ for the Born effective charge, and ${\ensuremath{\alpha}}^{\ensuremath{\perp}}=0.44$ for the polaron coupling constant are derived. Reflectivity measurements at 50\ifmmode^\circ\else\textdegree\fi{} incidence with $s$ and $p$ polarizations show that the longitudinal lattice mode is nearly isotropic. Using the value ${\ensuremath{\omega}}_{\mathrm{TO}}^{\ensuremath{\parallel}}=533$ ${\mathrm{cm}}^{\ensuremath{-}1}$ from Raman data the values ${\ensuremath{\omega}}_{\mathrm{LO}}^{\ensuremath{\parallel}}=744$ ${\mathrm{cm}}^{\ensuremath{-}1}$, ${\ensuremath{\epsilon}}_{o}^{\ensuremath{\parallel}}=10.4$, ${e}_{B}^{*\ensuremath{\parallel}}=2.82e$, and ${\ensuremath{\alpha}}^{\ensuremath{\parallel}}=0.49$ are obtained from oscillator fits to the 50\ifmmode^\circ\else\textdegree\fi{} incidence data. Information on the free-carrier effects in GaN was obtained by studying the normal-incidence reflectance as a function of carrier concentration in the 2\ifmmode\times\else\texttimes\fi{}${10}^{17}$ to 1\ifmmode\times\else\texttimes\fi{}${10}^{20}$ ${\mathrm{cm}}^{\ensuremath{-}3}$ range. By fitting the reflectance minima versus concentration data, a value of $\frac{{m}^{*}}{m}=(0.20\ifmmode\pm\else\textpm\fi{}0.02)$ for the optical effective mass is obtained. Measurements at 50\ifmmode^\circ\else\textdegree\fi{} incidence show that the plasma frequency is isotropic within experimental precision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.7.743

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 744

Metadata

Authors
Barker, A. S., & Ilegems, M.
Venue
Physical Review B
Published
1973-01-15
Volume
7
Issue
2
Pages
743-750
ISSN
0556-2805 (ISSN-L)
OpenAlex
W2003258254
Cited by
744
References
4
FWCI
3.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Infrared Lattice Vibrations and Free-Electron Dispersion in GaN. https://app.cochat.ai/papers/10.1103/physrevb.7.743
The paper
Barker, A. S., & Ilegems, M. (1973). Infrared Lattice Vibrations and Free-Electron Dispersion in GaN. Physical Review B. https://doi.org/10.1103/physrevb.7.743

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.