Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 230

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Low-temperature polymorphs ofZrO2andHfO2: A density-functional theory study

Jaffe, John E., Bachorz, Rafał A., Gutowski, Maciej · 2005 · Physical Review B

Abstract

The total energy and equation of state of the monoclinic, tetragonal, cubic, orthorhombic-I (Pbca) and orthorhombic-II (cotunnite) phases of zirconia and hafnia are determined using density functional theory (DFT) in the local density (LDA) and generalized-gradient (GGA) approximations. It is found that GGA corrections are needed to obtain low-temperature phase transitions under pressure that are consistent with experiment, i.e., $(\text{monoclinic}\ensuremath{\rightarrow}\text{orthorhombic}\text{\ensuremath{-}}I\ensuremath{\rightarrow}\text{cotunnite})$. The GGA values of the bulk modulus of the cotunnite phase are found to be 251 and $259\phantom{\rule{0.3em}{0ex}}\mathrm{GPa}$ for $\mathrm{Zr}{\mathrm{O}}_{2}$ and $\mathrm{Hf}{\mathrm{O}}_{2}$ respectively, highlighting the similarity of these two compounds. We introduce a population analysis scheme in which atomic radii are adapted to the actual charge distribution in the material. The results indicate that the effective atomic radius of Hf is smaller than that of Zr, a drastic manifestation of the relativistic lanthanide contraction. The population analysis demonstrates that ionicity: (i) decreases from the monoclinic to the cotunnite phase, and (ii) is larger for $\mathrm{Hf}{\mathrm{O}}_{2}$ than for $\mathrm{Zr}{\mathrm{O}}_{2}$. The bandgap and heat of formation are also larger for monoclinic $\mathrm{Hf}{\mathrm{O}}_{2}$ than for $\mathrm{Zr}{\mathrm{O}}_{2}$ by $0.60\phantom{\rule{0.3em}{0ex}}\mathrm{eV}$ and $0.60\phantom{\rule{0.3em}{0ex}}\mathrm{eV}$/ formula unit, respectively. The tetragonal phase, which often exists as a metastable phase at ambient conditions, has a bandgap larger than the monoclinic phase by 0.35 and $0.65\phantom{\rule{0.3em}{0ex}}\mathrm{eV}$ for $\mathrm{Zr}{\mathrm{O}}_{2}$ and $\mathrm{Hf}{\mathrm{O}}_{2}$, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.72.144107

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 230

Metadata

Authors
Jaffe, J. E., Bachorz, R. A., & Gutowski, M.
Venue
Physical Review B
Published
2005-10-20
Volume
72
Issue
14
ISSN
  • 1098-0121 (ISSN-L)
  • 1550-235X
OpenAlex
W2926856315
Cited by
230
References
3
FWCI
9.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.