The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced dc magnetic field sensitivity
Open accessAbstract
We report a systematic study of the magnetic field sensitivity of a magnetic sensor consisting of a single nitrogen-vacancy (NV) defect in diamond, by using continuous optically detected electron spin resonance (ESR) spectroscopy. We first investigate the behavior of the ESR contrast and linewidth as a function of the microwave and optical pumping power. The experimental results are in good agreement with a simplified model of the NV defect spin dynamics, leading to an optimized sensitivity around $2\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}$T$/\sqrt{\mathrm{Hz}}$ for a single NV defect in a high-purity diamond crystal grown by chemical vapor deposition. We then demonstrate an enhancement of the magnetic sensitivity by one order of magnitude by using a simple pulsed-ESR scheme. This technique is based on repetitive excitation of the NV defect with a resonant microwave $\ensuremath{\pi}$ pulse followed by an optimized readout laser pulse, allowing to fully eliminate power broadening of the ESR linewidth. The achieved sensitivity is similar to that obtained by using Ramsey-type sequences, which is the optimal magnetic field sensitivity for the detection of a dc magnetic field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoscale imaging magnetometry with diamond spins under ambient conditions
Balasubramanian, G., Chan, I. Y., Kolesov, R., Al-Hmoud, M., Tisler, J., Shin, C., Kim, C., Wojcik, A., Hemmer, P. R., Krueger, A., et al. (2008) · Nature · doi:10.1038/nature07278 · Cited by 1,999
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Ultralong spin coherence time in isotopically engineered diamond
Balasubramanian, G., Neumann, P., Twitchen, D., Markham, M., Kolesov, R., Mizuochi, N., Isoya, J., Achard, J., Beck, J., Tissler, J., et al. (2009) · Nature Materials · doi:10.1038/nmat2420 · Cited by 1,936
Self-citationBudker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Scanning Confocal Optical Microscopy and Magnetic Resonance on Single Defect Centers
Gruber, A., Dräbenstedt, A., Tietz, C., Fleury, L., Wrachtrup, J., & Borczyskowski, C. V. (1997) · Science · doi:10.1126/science.276.5321.2012 · Cited by 1,827
Electric-field sensing using single diamond spins
Dolde, F., Fedder, H., Doherty, M. W., Nöbauer, T., Rempp, F., Balasubramanian, G., Wolf, T., Reinhard, F., Hollenberg, L. C. L., Jelezko, F., et al. (2011) · Nature Physics · doi:10.1038/nphys1969 · Cited by 1,334
Quantum register based on individual electronic and nuclear spin qubits in diamond
Dutt, M. V. G., Childress, L., Jiang, L., Togan, E., Maze, J., Jelezko, F., Zibrov, A. S., Hemmer, P. R., & Lukin, M. D. (2007) · Science · doi:10.1126/science.1139831 · Cited by 1,287
Quantum entanglement between an optical photon and a solid-state spin qubit
Togan, E., Chu, Y., Trifonov, A. S., Jiang, L., Maze, J., Childress, L., Dutt, M. V. G., Sørensen, A. S., Hemmer, P. R., Zibrov, A. S., et al. (2010) · Nature · doi:10.1038/nature09256 · Cited by 1,200
Zaitsev, A. M. (2001) · Springer eBooks · doi:10.1007/978-3-662-04548-0 · Cited by 1,120
Cited by
Magnetometry with nitrogen-vacancy defects in diamond
Rondin, L., Tetienne, J.-P., Hingant, T., Roch, J.-F., Maletinsky, P., & Jacques, V (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/5/056503 · Cited by 1,336
Self-citationSensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
A robust scanning diamond sensor for nanoscale imaging with single nitrogen-vacancy centres
Maletinsky, P., Hong, S., Grinolds, M. S., Hausmann, B., Lukin, M. D., Walsworth, R. L., Loncar, M., & Yacoby, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.50 · Cited by 726
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Strain Coupling of a Nitrogen-Vacancy Center Spin to a Diamond Mechanical Oscillator
Teissier, J., Barfuss, A., Appel, P., Neu, E., & Maletinsky, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.020503 · Cited by 350
Metadata
- Authors
- Dréau, A., Lesik, M., Rondin, L., Spinicelli, P., Arcizet, O., Roch, J.-F., & Jacques, V.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2011-11-23
- Volume
- 84
- Issue
- 19
- ISSN
- 1098-0121 (ISSN-L)
- 1550-235X
- OpenAlex
- W1978690458
- Cited by
- 523
- References
- 37
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced dc magnetic field sensitivity. https://app.cochat.ai/papers/10.1103/physrevb.84.195204
- The paper
- Dréau, A., Lesik, M., Rondin, L., Spinicelli, P., Arcizet, O., Roch, J.-F., & Jacques, V. (2011). Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced dc magnetic field sensitivity. Physical Review B. https://doi.org/10.1103/physrevb.84.195204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.