The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Universal back-projection algorithm for photoacoustic computed tomography
Abstract
We report results of a reconstruction algorithm for three-dimensional photoacoustic computed tomography. A universal back-projection formula is presented for three types of imaging geometries: planar, spherical, and cylindrical surfaces. A solid-angle weighting factor is introduced in the back-projection formula to compensate for the variations of detection views. A method for implementing this algorithm is described. Numerical simulation is used to demonstrate the performance of the algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Morse, P. M., Ingard, K. U., & Beyer, R. T. (1969) · Journal of Applied Mechanics · doi:10.1115/1.3564682 · Cited by 3,188
Ahmadivand, A., Gerislioglu, B., & Ramezani, Z. (2021) · Engineering Materials · doi:10.1007/978-3-030-58288-3_2 · Cited by 1,636
Applications of photoacoustic sensing techniques
Tam, A. C. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.381 · Cited by 1,306
Mathematical Methods for Physicists
(1995) · Elsevier eBooks · doi:10.1016/c2009-1-28537-6 · Cited by 1,255
Physical properties of tissue: F. A. Duck Harcourt Brace Jovanovich Ltd, London; 1990, 346 pp.
Bowker, P. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90034-5 · Cited by 608
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461
Self-citationDetermining a Function from Its Mean Values Over a Family of Spheres
Finch, D., & Patch, S. K. (2004) · SIAM Journal on Mathematical Analysis · doi:10.1137/s0036141002417814 · Cited by 410
Photoacoustic monopole radiation in one, two, and three dimensions
Diebold, G. J., Sun, T., & Khan, M. I. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.3384 · Cited by 353
Xu, M., Xu, Y., & Wang, L. V. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816081 · Cited by 274
Self-citation
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationPhotoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationBiomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationKim, C., Favazza, C., & Wang, L. V. (2010) · Chemical Reviews · doi:10.1021/cr900266s · Cited by 807
Self-citation
Metadata
- Authors
- Xu, M., & Wang, L. V.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2005-01-19
- Volume
- 71
- Issue
- 1
- Pages
- 016706-016706
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W2092513871
- Cited by
- 1,243
- References
- 10
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.