The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Cavitation pressure in water
Abstract
We investigate the limiting mechanical tension (negative pressure) that liquid water can sustain before cavitation occurs. The temperature dependence of this quantity is of special interest for water, where it can be used as a probe of a postulated anomaly of its equation of state. After a brief review of previous experiments on cavitation, we describe our method which consists in focusing a high amplitude sound wave in the bulk liquid, away from any walls. We obtain highly reproducible results, allowing us to study in detail the statistics of cavitation, and to give an accurate definition of the cavitation threshold. Two independent pressure calibrations are performed. The cavitation pressure is found to increase monotonically from $\ensuremath{-}26\phantom{\rule{0.3em}{0ex}}\mathrm{MPa}$ at $0\phantom{\rule{0.2em}{0ex}}\ifmmode^\circ\else\textdegree\fi{}\mathrm{C}$ to $\ensuremath{-}17\phantom{\rule{0.3em}{0ex}}\mathrm{MPa}$ at $80\phantom{\rule{0.2em}{0ex}}\ifmmode^\circ\else\textdegree\fi{}\mathrm{C}$. While these values lie among the most negative pressures reported in water, they are still far away from the cavitation pressure expected theoretically and reached in the experiment by Angell and his group [Zheng et al., Science 254, 829 (1991)] (around $\ensuremath{-}120\phantom{\rule{0.3em}{0ex}}\mathrm{MPa}$ at $40\phantom{\rule{0.2em}{0ex}}\ifmmode^\circ\else\textdegree\fi{}\mathrm{C}$). Possible reasons for this discrepancy are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Savitzky-Golay Smoothing Filters
Press, W. H., & Teukolsky, S. A. (1990) · Computers in Physics · doi:10.1063/1.4822961 · Cited by 11,670
Kinetische Behandlung der Keimbildung in übersättigten Dämpfen
Becker, R., & Döring, W. (1935) · Annalen der Physik · doi:10.1002/andp.19354160806 · Cited by 3,155
Leighton, T. G. (2012) · Cited by 2,284
Phase behaviour of metastable water
Poole, P. H., Sciortino, F., Essmann, U., & Stanley, H. E. (1992) · Nature · doi:10.1038/360324a0 · Cited by 1,870
Fisher, J. C. (1948) · Journal of Applied Physics · doi:10.1063/1.1698012 · Cited by 537
Wohl, C. G., Cahn, R. N., Rittenberg, A., Trippe, T. G., Yost, G. P., Porter, F. C., Hernandez, J. J., Montanet, L., Hendrick, R. E., Crawford, R. L., et al. (1984) · Reviews of Modern Physics · doi:10.1103/revmodphys.56.s1 · Cited by 454
Leighton, T. G., & Apfel, R. E. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.410082 · Cited by 427
Liquids at Large Negative Pressures: Water at the Homogeneous Nucleation Limit
Zheng, Q., Durben, D. J., Wolf, G. H., & Angell, C. A. (1991) · Science · doi:10.1126/science.254.5033.829 · Cited by 420
Limiting Negative Pressure of Water
Briggs, L. J. (1950) · Journal of Applied Physics · doi:10.1063/1.1699741 · Cited by 376
Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
Holland, C. K., & Apfel, R. E. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.400102 · Cited by 310
Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water
Staudenraus, J., & Eisenmenger, W. (1993) · Ultrasonics · doi:10.1016/0041-624x(93)90020-z · Cited by 270
Experimental investigation of cavitation in superfluid He4
Pettersen, M. S., Balibar, S., & Maris, H. J. (1994) · Physical review. B, Condensed matter · doi:10.1103/physrevb.49.12062 · Cited by 74
Self-citationTensile strength of liquid He4
Nissen, J. A., Bodegom, E., Brodie, L. C., & Semura, J. S. (1989) · Physical review. B, Condensed matter · doi:10.1103/physrevb.40.6617 · Cited by 67
Cited by
The transpiration of water at negative pressures in a synthetic tree
Wheeler, T. D., & Stroock, A. D. (2008) · Nature · doi:10.1038/nature07226 · Cited by 572
Caupin, F., & Herbert, E. (2006) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2006.10.015 · Cited by 471
Self-citationGeneralized Soil Water Retention Equation for Adsorption and Capillarity
Lu, N. (2016) · Journal of Geotechnical and Geoenvironmental Engineering · doi:10.1061/(asce)gt.1943-5606.0001524 · Cited by 318
Metadata
- Authors
- Herbert, E., Balibar, S., & Caupin, F.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2006-10-16
- Volume
- 74
- Issue
- 4
- Pages
- 041603-041603
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W1981780967
- Cited by
- 338
- References
- 13
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.