The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Determination of the Newtonian Gravitational Constant Using Atom Interferometry
Open accessAbstract
We present a new measurement of the Newtonian gravitational constant $G$ based on cold-atom interferometry. Freely falling samples of laser-cooled rubidium atoms are used in a gravity gradiometer to probe the field generated by nearby source masses. In addition to its potential sensitivity, this method is intriguing as gravity is explored by a quantum system. We report a value of $G=6.667\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}\text{ }\text{ }{\mathrm{m}}^{3}\text{ }{\mathrm{kg}}^{\ensuremath{-}1}\text{ }{\mathrm{s}}^{\ensuremath{-}2}$, estimating a statistical uncertainty of $\ifmmode\pm\else\textpm\fi{}0.011\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}\text{ }\text{ }{\mathrm{m}}^{3}\text{ }{\mathrm{kg}}^{\ensuremath{-}1}\text{ }{\mathrm{s}}^{\ensuremath{-}2}$ and a systematic uncertainty of $\ifmmode\pm\else\textpm\fi{}0.003\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}\text{ }\text{ }{\mathrm{m}}^{3}\text{ }{\mathrm{kg}}^{\ensuremath{-}1}\text{ }{\mathrm{s}}^{\ensuremath{-}2}$. The long-term stability of the instrument and the signal-to-noise ratio demonstrated here open interesting perspectives for pushing the measurement accuracy below the 100 ppm level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
Measurement of gravitational acceleration by dropping atoms
Peters, A., Chung, K. Y., & Chu, S. (1999) · Nature · doi:10.1038/23655 · Cited by 925
Precision Rotation Measurements with an Atom Interferometer Gyroscope
Gustavson, T. L., Bouyer, P., & Kasevich, M. A. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.2046 · Cited by 785
Sensitive absolute-gravity gradiometry using atom interferometry
McGuirk, J. M., Foster, G. T., Fixler, J. B., Snadden, M. J., & Kasevich, M. A. (2002) · Physical Review A · doi:10.1103/physreva.65.033608 · Cited by 586
Atom Interferometer Measurement of the Newtonian Constant of Gravity
Fixler, J. B., Foster, G. T., McGuirk, J. M., & Kasevich, M. A. (2007) · Science · doi:10.1126/science.1135459 · Cited by 554
Measurement of the gravitational acceleration of an atom with a light-pulse atom interferometer
Kasevich, M., & Chu, S. (1992) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00325375 · Cited by 550
Six-Axis Inertial Sensor Using Cold-Atom Interferometry
Canuel, B., Leduc, F., Holleville, D., Gauguet, A., Fils, J., Virdis, A., Clairon, A., Dimarcq, N., Bordé, C. J., Landragin, A., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.010402 · Cited by 387
Fray, S., Diez, C. A., Hänsch, T. W., & Weitz, M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.240404 · Cited by 303
Measurement of Newton's Constant Using a Torsion Balance with Angular Acceleration Feedback
Gundlach, J. H., & Merkowitz, S. M. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2869 · Cited by 283
Ferrari, G., Poli, N., Sorrentino, F., & Tino, G. M. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.060402 · Cited by 265
Self-citationCladé, P., de Mirandes, E., Cadoret, M., Guellati-Khélifa, S., Schwob, C., Nez, F., Julien, L., & Biraben, F. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.033001 · Cited by 247
A New Determination of G Using Two Methods
Quinn, T., Speake, C. C., Richman, S., Davis, R., & Picard, A. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.111101 · Cited by 159
Bertoldi, A. D., Lamporesi, G., Cacciapuoti, L., de Angelis, M., Fattori, M., Petelski, T., Peters, A., Prevedelli, M., Stühler, J., & Tino, G. M. (2006) · The European Physical Journal D · doi:10.1140/epjd/e2006-00212-2 · Cited by 126
Self-citationMethod of phase extraction between coupled atom interferometers using ellipse-specific fitting
Foster, G. T., Fixler, J. B., McGuirk, J. M., & Kasevich, M. A. (2002) · Optics Letters · doi:10.1364/ol.27.000951 · Cited by 124
Bagley, C. H., & Luther, G. G. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.3047 · Cited by 124
Measurement of Newton’s gravitational constant
Schlamminger, S., Holzschuh, E., Kündig, W., Nolting, F., Pixley, R. E., Schurr, J., & Straumann, U. (2006) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.74.082001 · Cited by 118
New Measurements of G Using the Measurement Standards Laboratory Torsion Balance
Armstrong, T. R., & Fitzgerald, M. P. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.201101 · Cited by 89
A Free-Fall Determination of the Newtonian Constant of Gravity
Schwarz, J. P., Robertson, D. S., Niebauer, T. M., & Faller, J. E. (1998) · Science · doi:10.1126/science.282.5397.2230 · Cited by 78
Tino, G. M., Cacciapuoti, L., Bongs, K., Bordé, C. J., Bouyer, P., Dittus, H., Ertmer, W., Görlitz, A., Inguscio, M., Landragin, A., et al. (2007) · Nuclear Physics B - Proceedings Supplements · doi:10.1016/j.nuclphysbps.2006.12.061 · Cited by 52
Self-citationA new photon recoil experiment: towards a determination of the fine structure constant
Müller, H., Chiow, S., Long, Q., et al. (2006) · Applied Physics B · doi:10.1007/s00340-006-2279-x · Cited by 40
Status of measurement of the Newtonian gravitational constantG
Luo, J., & Hu, Z.-K. (2000) · Classical and Quantum Gravity · doi:10.1088/0264-9381/17/12/307 · Cited by 39
Absolute measurement of the Newtonian force and a determination ofG
Kleinevoss, U., Meyer, H., Schumacher, A., & Hartmann, S. (1999) · Measurement Science and Technology · doi:10.1088/0957-0233/10/6/313 · Cited by 33
Source mass and positioning system for an accurate measurement of G
Lamporesi, G., Bertoldi, A. D., Cecchetti, A., Duhlach, B., Fattori, M., Malengo, A., Pettorruso, S., Prevedelli, M., & Tino, G. M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2751090 · Cited by 26
Self-citation
Cited by
Precision measurement of the Newtonian gravitational constant using cold atoms
Rosi, G., Sorrentino, F., Cacciapuoti, L., Prevedelli, M., & Tino, G. M. (2014) · Nature · doi:10.1038/nature13433 · Cited by 739
Self-citationNew Method for Gravitational Wave Detection with Atomic Sensors
Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.171102 · Cited by 346
Limits to the sensitivity of a low noise compact atomic gravimeter
Le Gouët, J., Mehlstäubler, T. E., Kim, J., Merlet, S., Clairon, A., Landragin, A., & Pereira Dos Santos, F. (2008) · Applied Physics B · doi:10.1007/s00340-008-3088-1 · Cited by 294
Precision measurement of the Newtonian gravitational constant
Xue, C., Liu, J.-P., Li, Q., Wu, J.-F., Yang, S.-Q., Liu, Q., Shao, C.-G., Tu, L.-C., Hu, Z.-K., & Luo, J. (2020) · National Science Review · doi:10.1093/nsr/nwaa165 · Cited by 60
Metadata
- Authors
- Lamporesi, G., Bertoldi, A., Cacciapuoti, L., Prevedelli, M., & Tino, G. M.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2008-02-08
- Volume
- 100
- Issue
- 5
- Pages
- 050801-050801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2015134619
- Cited by
- 277
- References
- 23
- FWCI
- 20.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.