Absolute Frequency Measurement of theCa+404s S1/22−3d D5/22Clock Transition
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
We report on the first absolute transition frequency measurement at the ${10}^{\ensuremath{-}15}$ level with a single, laser-cooled $^{40}\mathrm{Ca}^{+}$ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the $^{40}\mathrm{Ca}^{+}$ $4s\text{ }^{2}S_{1/2}\ensuremath{-}3d\text{ }^{2}D_{5/2}$ electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency ${\ensuremath{\nu}}_{{\mathrm{Ca}}^{+}}=411\text{ }042\text{ }129\text{ }776\text{ }393.2(1.0)\text{ }\text{ }\mathrm{Hz}$ is obtained, which corresponds to a fractional uncertainty within a factor of 3 of the Cs standard. In addition, we determine the Land\'e $g$ factor of the $3d^{2}D_{5/2}$ level to be ${g}_{5/2}=1.200\text{ }334\text{ }0(3)$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Optimal frequency measurements with maximally correlated states
Bollinger, J. J., Itano, W. M., Wineland, D. J., & Heinzen, D. J. (1996) · Physical Review A · doi:10.1103/physreva.54.r4649 · Cited by 1,167
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Toward Heisenberg-Limited Spectroscopy with Multiparticle Entangled States
Leibfried, D., Barrett, M. D., Schaetz, T., Britton, J., Chiaverini, J., Itano, W. M., Jost, J. D., Langer, C., & Wineland, D. J. (2004) · Science · doi:10.1126/science.1097576 · Cited by 661
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Towards fault-tolerant quantum computing with trapped ions
Benhelm, J., Kirchmair, G., Roos, C. F., & Blatt, R. (2008) · Nature Physics · doi:10.1038/nphys961 · Cited by 526
Self-citation‘Designer atoms’ for quantum metrology
Roos, C. F., Chwalla, M., Kim, K., Riebe, M., & Blatt, R. (2006) · Nature · doi:10.1038/nature05101 · Cited by 343
Self-citationHertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationCold atom clocks and applications
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Santos, F. P. D., Rosenbusch, P., et al. (2005) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/38/9/002 · Cited by 239
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Theory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 489
Single-Ion Nuclear Clock for Metrology at the 19th Decimal Place
Campbell, C. J., Radnaev, A. G., Kuzmich, A., Dzuba, V. A., Flambaum, V. V., & Derevianko, A. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.120802 · Cited by 347
A quantum information processor with trapped ions
Schindler, P., Nigg, D., Monz, T., Barreiro, J. T., Martinez, E., Wang, S. X., Quint, S., Brandl, M. F., Nebendahl, V., Roos, C. F., et al. (2013) · New Journal of Physics · doi:10.1088/1367-2630/15/12/123012 · Cited by 342
Self-citationProgress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationMehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“2011) or the (40)Ca clock transition frequency (Chwalla et al. 2009).”
Probing New Long-Range Interactions by Isotope Shift Spectroscopy
Berengut, J. C., Budker, D., Delaunay, C., Flambaum, V. V., Frugiuele, C., Fuchs, E., Grojean, C., Harnik, R., Ozeri, R., Perez, G., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.091801 · Cited by 184
Light-matter entanglement over 50 km of optical fibre
Krutyanskiy, V., Meraner, M., Schupp, J., Krcmarsky, V., Hainzer, H., & Lanyon, B. P. (2019) · npj Quantum Information · doi:10.1038/s41534-019-0186-3 · Cited by 138
Optimal distributed sensing in noisy environments
Sekatski, P., Wölk, S., & Dür, W. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.023052 · Cited by 58
Toward an ion–photon quantum interface in an optical cavity
Stute, A., Casabone, B., Brandstätter, B., Habicher, D., Barros, H. G., Schmidt, P. O., Northup, T. E., & Blatt, R. (2012) · Applied Physics B · doi:10.1007/s00340-011-4861-0 · Cited by 36
Self-citationTransportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Metadata
- Authors
- Chwalla, M., Benhelm, J., Kim, K., Kirchmair, G., Monz, T., Riebe, M., Schindler, P., Villar, A. S., Hänsel, W., Roos, C. F., Blatt, R., Abgrall, M., Santarelli, G., Rovera, G. D., & Laurent, P.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2009-01-13
- Volume
- 102
- Issue
- 2
- Pages
- 023002-023002
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1584710694
- Cited by
- 164
- References
- 25
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.