The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Extreme Ultraviolet Frequency Comb Metrology
Open accessAbstract
The remarkable precision of frequency-comb (FC) lasers is transferred to the extreme ultraviolet (XUV, wavelengths shorter than 100 nm), a frequency region previously not accessible to these devices. A frequency comb at XUV wavelengths near 51 nm is generated by amplification and coherent up-conversion of a pair of pulses originating from a near-infrared femtosecond FC laser. The phase coherence of the source in the XUV is demonstrated using helium atoms as a ruler and phase detector. Signals in the form of stable Ramsey-like fringes with high contrast are observed when the FC laser is scanned over P states of helium, from which the absolute transition frequency in the XUV can be extracted. This procedure yields a (4)He ionization energy at h×5 945 204 212(6) MHz, improved by nearly an order of magnitude in accuracy, thus challenging QED calculations of this two-electron system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attosecond control of electronic processes by intense light fields
Baltuška, A., Udem, T., Uiberacker, M., Hentschel, M., Goulielmakis, E., Gohle, C., Holzwarth, R., Yakovlev, V. S., Scrinzi, A., Hänsch, T. W., et al. (2003) · Nature · doi:10.1038/nature01414 · Cited by 1,653
Self-citationFrequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
The evolving optical frequency comb [Invited]
Diddams, S. A. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.000b51 · Cited by 615
Direct frequency comb spectroscopy in the extreme ultraviolet
Cingöz, A., Yost, D. C., Allison, T. K., Ruehl, A., Fermann, M. E., Hartl, I., & Ye, J. (2012) · Nature · doi:10.1038/nature10711 · Cited by 477
Angular dependence of photoemission time delay in helium
Heuser, S., Jiménez Galán, Á., Cirelli, C., Marante, C., Sabbar, M., Boge, R., Lucchini, M., Gallmann, L., Ivanov, I., Kheifets, A. S., et al. (2016) · Physical Review A · doi:10.1103/physreva.94.063409 · Cited by 161
Precision spectroscopy of helium in a magic wavelength optical dipole trap
Rengelink, R. J., van der Werf, Y., Notermans, R. P. M. J. W., Jannin, R., Eikema, K. S. E., Hoogerland, M. D., & Vassen, W. (2018) · Nature Physics · doi:10.1038/s41567-018-0242-5 · Cited by 66
Self-citation
Metadata
- Authors
- Kandula, D. Z., Gohle, C., Pinkert, T. J., Ubachs, W., & Eikema, K. S. E.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2010-08-02
- Volume
- 105
- Issue
- 6
- Pages
- 063001-063001
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1970974590
- Cited by
- 174
- References
- 3
- FWCI
- 9.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extreme Ultraviolet Frequency Comb Metrology. https://app.cochat.ai/papers/10.1103/physrevlett.105.063001
- The paper
- Kandula, D. Z., Gohle, C., Pinkert, T. J., Ubachs, W., & Eikema, K. S. E. (2010). Extreme Ultraviolet Frequency Comb Metrology. Physical Review Letters. https://doi.org/10.1103/physrevlett.105.063001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.