The DOI matches its Crossref record.
Real Time Magnetic Field Sensing and Imaging Using a Single Spin in Diamond
Open accessAbstract
The Zeeman splitting of a localized single spin can be used to construct a highly sensitive magnetometer offering almost atomic spatial resolution. While sub-μT sensitivity can be obtained in principle using pulsed techniques and long measurement times, a fast and easy method without laborious data postprocessing is desirable for a scanning-probe approach with high spatial resolution. In order to measure the resonance frequency in real time, we applied a field-frequency lock to the optically detected magnetic resonance signal of a single electron spin in a nanodiamond. We achieved a sampling rate of up to 100 readings per sec with a sensitivity of 6 μT/sqrt[Hz]. Images of the field distribution around a magnetic wire were acquired with ∼30 μT resolution and 4096 submicron sized pixels in 10 min. The response of several spins was used to reconstruct the field orientation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nitrogen-Vacancy Centers in Diamond: Nanoscale Sensors for Physics and Biology
Schirhagl, R., Chang, K., Loretz, M., & Degen, C. L. (2014) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040513-103659 · Cited by 1,608
Magnetometry with nitrogen-vacancy defects in diamond
Rondin, L., Tetienne, J.-P., Hingant, T., Roch, J.-F., Maletinsky, P., & Jacques, V (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/5/056503 · Cited by 1,336
Sensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Dréau, A., Lesik, M., Rondin, L., Spinicelli, P., Arcizet, O., Roch, J.-F., & Jacques, V. (2011) · Physical Review B · doi:10.1103/physrevb.84.195204 · Cited by 523
Metadata
- Authors
- Schoenfeld, R. S., & Harneit, W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2011-01-18
- Volume
- 106
- Issue
- 3
- Pages
- 030802-030802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1996745600
- Cited by
- 162
- References
- 0
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real Time Magnetic Field Sensing and Imaging Using a Single Spin in Diamond. https://app.cochat.ai/papers/10.1103/physrevlett.106.030802
- The paper
- Schoenfeld, R. S., & Harneit, W. (2011). Real Time Magnetic Field Sensing and Imaging Using a Single Spin in Diamond. Physical Review Letters. https://doi.org/10.1103/physrevlett.106.030802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.