The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Cavity Optomechanical Magnetometer
Open accessAbstract
A cavity optomechanical magnetometer is demonstrated. The magnetic-field-induced expansion of a magnetostrictive material is resonantly transduced onto the physical structure of a highly compliant optical microresonator and read out optically with ultrahigh sensitivity. A peak magnetic field sensitivity of $400\text{ }\text{ }\mathrm{nT}\text{ }{\mathrm{Hz}}^{\ensuremath{-}1/2}$ is achieved, with theoretical modeling predicting the possibility of sensitivities below $1\text{ }\text{ }\mathrm{pT}\text{ }{\mathrm{Hz}}^{\ensuremath{-}1/2}$. This chip-based magnetometer combines high sensitivity and large dynamic range with small size and room temperature operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Ultralong spin coherence time in isotopically engineered diamond
Balasubramanian, G., Neumann, P., Twitchen, D., Markham, M., Kolesov, R., Mizuochi, N., Isoya, J., Achard, J., Beck, J., Tissler, J., et al. (2009) · Nature Materials · doi:10.1038/nmat2420 · Cited by 1,936
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Ultracompact optical buffers on a silicon chip
Xia, F., Sekaric, L., & Vlasov, Y. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.42 · Cited by 1,123
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Advances in Magnetic Field Sensors
Ripka, P., & Janosek, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2043429 · Cited by 546
Cleland, A. N. (2003) · Advanced texts in physics · doi:10.1007/978-3-662-05287-7 · Cited by 538
Design and application of magnetostrictive materials
Olabi, A. G., & Grunwald, A. (2008) · Materials & Design · doi:10.1016/j.matdes.2006.12.016 · Cited by 500
Cited by
Aspelmeyer, M., Kippenberg, T. J., & Marquardt, F. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.1391 · Cited by 5,501
Exceptional points enhance sensing in an optical microcavity
Chen, W., Kaya Özdemir, Ş., Zhao, G., Wiersig, J., & Yang, L. (2017) · Nature · doi:10.1038/nature23281 · Cited by 2,084
Whispering gallery mode sensors
Foreman, M. R., Swaim, J. D., & Vollmer, F. (2015) · Advances in Optics and Photonics · doi:10.1364/aop.7.000168 · Cited by 927
Self-citationNon-Hermitian Topological Sensors
Budich, J. C., & Bergholtz, E. J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.180403 · Cited by 394
Jiang, X., Qavi, A. J., Huang, S. H., & Yang, L. (2020) · Matter · doi:10.1016/j.matt.2020.07.008 · Cited by 353
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“One type of magnetic field sensor having linear dimensions of tenths of micrometers [141], and the lowest detection level of the order of about 100 pT/√Hz [142] (at room temperature) is the cavity optomechanical magnetometer [143].”
BackgroundApplications of cavity optomechanics
Metcalfe, M. (2014) · Applied Physics Reviews · doi:10.1063/1.4896029 · Cited by 274
Precision measurement of electrical charge with optomechanically induced transparency
Zhang, J.-Q., Li, Y., Feng, M., & Xu, Y. (2012) · Physical Review A · doi:10.1103/physreva.86.053806 · Cited by 253
Nair, J. M. P., Mukhopadhyay, D., & Agarwal, G. S. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.180401 · Cited by 97
Metadata
- Authors
- Forstner, S., Prams, S., Knittel, J., van Ooijen, E. D., Swaim, J. D., Harris, G. I., Szorkovszky, A., Bowen, W. P., & Rubinsztein-Dunlop, H.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-03-21
- Volume
- 108
- Issue
- 12
- Pages
- 120801-120801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2128938328
- Cited by
- 303
- References
- 35
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.