The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantum Metrology Enhanced by Repetitive Quantum Error Correction
Open accessAbstract
We experimentally demonstrate the protection of a room-temperature hybrid spin register against environmental decoherence by performing repeated quantum error correction whilst maintaining sensitivity to signal fields. We use a long-lived nuclear spin to correct multiple phase errors on a sensitive electron spin in diamond and realize magnetic field sensing beyond the time scales set by natural decoherence. The universal extension of sensing time, robust to noise at any frequency, demonstrates the definitive advantage entangled multiqubit systems provide for quantum sensing and offers an important complement to quantum control techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Realization of quantum error correction
Chiaverini, J., Leibfried, D., Schaetz, T., Barrett, M. D., Blakestad, R. B., Britton, J., Itano, W. M., Jost, J. D., Knill, E., Langer, C., et al. (2004) · Nature · doi:10.1038/nature03074 · Cited by 517
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Submillihertz magnetic spectroscopy performed with a nanoscale quantum sensor
Schmitt, S., Gefen, T., Stürner, F. M., Unden, T., Wolff, G., Müller, C., Scheuer, J., Naydenov, B., Markham, M., Pezzagna, S., et al. (2017) · Science · doi:10.1126/science.aam5532 · Cited by 359
Self-citationOne-second coherence for a single electron spin coupled to a multi-qubit nuclear-spin environment
Abobeih, M. H., Cramer, J., Bakker, M. A., Kalb, N., Markham, M., Twitchen, D. J., & Taminiau, T. H. (2018) · Nature Communications · doi:10.1038/s41467-018-04916-z · Cited by 302
Self-citationPractical limits of error correction for quantum metrology
Shettell, N., Munro, W. J., Markham, D., & Nemoto, K. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abf533 · Cited by 23
Metadata
- Authors
- Unden, T., Balasubramanian, P., Louzon, D., Vinkler, Y., Plenio, M. B., Markham, M., Twitchen, D., Stacey, A., Lovchinsky, I., Sushkov, A. O., Lukin, M. D., Retzker, A., Naydenov, B., McGuinness, L. P., & Jelezko, F.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2016-06-09
- Volume
- 116
- Issue
- 23
- Pages
- 230502-230502
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2301999234
- Cited by
- 160
- References
- 2
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantum Metrology Enhanced by Repetitive Quantum Error Correction. https://app.cochat.ai/papers/10.1103/physrevlett.116.230502
- The paper
- Unden, T., Balasubramanian, P., Louzon, D., Vinkler, Y., Plenio, M. B., Markham, M., Twitchen, D., Stacey, A., Lovchinsky, I., Sushkov, A. O., Lukin, M. D., Retzker, A., Naydenov, B., McGuinness, L. P., & Jelezko, F. (2016). Quantum Metrology Enhanced by Repetitive Quantum Error Correction. Physical Review Letters. https://doi.org/10.1103/physrevlett.116.230502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.