The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
1.5 μm Lasers with Sub-10 mHz Linewidth
Open accessAbstract
We report on two ultrastable lasers each stabilized to independent silicon Fabry-Pérot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of the mirror coatings with a flicker noise floor of 4×10^{-17} for integration times between 0.8 s and a few tens of seconds. We rigorously treat the notorious divergences encountered with the associated flicker frequency noise and derive methods to relate this noise to observable and practically relevant linewidths and coherence times. The individual laser linewidth obtained from the phase noise spectrum or the direct beat note between the two lasers can be as small as 5 mHz at 194 THz. From the measured phase evolution between the two laser fields we derive usable phase coherence times for different applications of 11 to 55 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Saleh, B. E. A., & Teich, M. C. (1991) · doi:10.1002/0471213748 · Cited by 3,383
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationInterferometry and Synthesis in Radio Astronomy
Thompson, A. R., Moran, J. M., & Swenson, G. W. (2001) · Wiley eBooks · doi:10.1002/9783527617845 · Cited by 1,446
A fully photonics-based coherent radar system
Ghelfi, P., Laghezza, F., Scotti, F., Serafino, G., Capria, A., Pinna, S., Onori, D., Porzi, C., Scaffardi, M., Malacarne, A., et al. (2014) · Nature · doi:10.1038/nature13078 · Cited by 1,111
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · cited 2×
“Ye, “An Optical Lattice Clock with Accuracy and Stability at the 10 Level”, Nature 506, 71-75 (2014) [2] N.”
BackgroundCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
1/fnoise: Implications for solid-state quantum information
Paladino, E., Galperin, Y. M., Falci, G., & Altshuler, B. L. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.361 · Cited by 609
Ma, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Self-citationThermal-Noise Limit in the Frequency Stabilization of Lasers with Rigid Cavities
Numata, K., Kemery, A., & Camp, J. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.250602 · Cited by 554
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Gravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396
Self-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
Self-citationTenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 382
Self-citation8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Self-citationCharacterization of clocks and oscillators
Allan, D. W., Howe, D. A., Walls, F. L., & Sullivan, D. B. (1990) · doi:10.6028/nist.tn.1337 · Cited by 271
Kerr-lens, mode-locked lasers as transfer oscillators for optical frequency measurements
Telle, H. R., Lipphardt, B., & Stenger, J. (2002) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400100735 · Cited by 242
Should the classical variance be used as a basic measure in standards metrology?
Allan, D. W. (1987) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1987.6312761 · Cited by 237
Considerations on the measurement of the stability of oscillators with frequency counters
Dawkins, S. T., McFerran, J. J., & Luiten, A. N. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2007.337 · Cited by 220
A Quantum Many-Body Spin System in an Optical Lattice Clock
Martin, M. J., Bishof, M., Swallows, M. D., Zhang, X., Benko, C., von-Stecher, J., Gorshkov, A. V., Rey, A. M., & Ye, J. (2013) · Science · doi:10.1126/science.1236929 · Cited by 196
Self-citationKerr-lens mode-locked lasers as transfer oscillators for optical frequency measurements
Telle, H. R., Lipphardt, B., & Stenger, J. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 191
Zhang, W., Martin, M. J., Benko, C., Hall, J. L., Ye, J., Hagemann, C., Legero, T., Sterr, U., Riehle, F., Cole, G. D., et al. (2014) · Optics Letters · doi:10.1364/ol.39.001980 · Cited by 184
Self-citationHigh-performance near- and mid-infrared crystalline coatings
Cole, G. D., Zhang, W., Bjork, B. J., Follman, D., Heu, P., Deutsch, C., Sonderhouse, L., Robinson, J., Franz, C., Alexandrovski, A., et al. (2016) · Optica · doi:10.1364/optica.3.000647 · Cited by 179
Self-citationA Method for Estimating the Frequency Stability of an Individual Oscillator
Gray, J. E., & Allan, D. W. (1974) · 28th Annual Symposium on Frequency Control · doi:10.1109/freq.1974.200027 · Cited by 170
Ultraprecise Measurement of Optical Frequency Ratios
Stenger, J., Schnatz, H., Tamm, C., & Telle, H. R. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.073601 · Cited by 157
Cold-Strontium Laser in the Superradiant Crossover Regime
Norcia, M. A., & Thompson, J. K. (2016) · Physical Review X · doi:10.1103/physrevx.6.011025 · Cited by 132
Heisenberg-Limited Atom Clocks Based on Entangled Qubits
Kessler, E. M., Kómár, P., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.190403 · Cited by 131
Self-citationLaser line shape and spectral density of frequency noise
Stéphan, G. M., Tam, T. T., Blin, S., Besnard, P., & Têtu, M. (2005) · Physical Review A · doi:10.1103/physreva.71.043809 · Cited by 122
On the measurement of frequency and of its sample variance with high-resolution counters
Rubiola, E. (2005) · Review of Scientific Instruments · doi:10.1063/1.1898203 · Cited by 120
Atom-interferometric gravitational-wave detection using heterodyne laser links
Hogan, J. M., & Kasevich, M. A. (2016) · Physical Review A · doi:10.1103/physreva.94.033632 · Cited by 118
Walls, F. L., & Wainwright, A. E. (1975) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1975.4314362 · Cited by 111
Ultrastable laser with average fractional frequency drift rate below 5 × 10^−19/s
Hagemann, C., Grebing, C., Lisdat, C., Falke, S., Legero, T., Sterr, U., Riehle, F., Martin, M. J., & Ye, J. (2014) · Optics Letters · doi:10.1364/ol.39.005102 · Cited by 92
Self-citationOptical Spectrum Analyzer with Quantum-Limited Noise Floor
Bishof, M., Zhang, X., Martin, M. J., & Ye, J. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.093604 · Cited by 84
Self-citationBenkler, E., Lisdat, C., & Sterr, U. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/565 · Cited by 77
Self-citationProbing many-body interactions in an optical lattice clock
Rey, A. M., Gorshkov, A. V., Kraus, C. V., Martin, M. J., Bishof, M., Swallows, M. D., Zhang, X., Benko, C., Ye, J., Lemke, N. D., et al. (2013) · Annals of Physics · doi:10.1016/j.aop.2013.11.002 · Cited by 76
Self-citationLaser-Frequency Stabilization Based on Steady-State Spectral-Hole Burning in Eu3+∶Y2SiO5
Cook, S., Rosenband, T., & Leibrandt, D. R. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.253902 · Cited by 68
Time-dependent laser linewidth: beat-note digital acquisition and numerical analysis
von Bandel, N., Myara, M., Sellahi, M., Souici, T., Dardaillon, R., & Signoret, P. (2016) · Optics Express · doi:10.1364/oe.24.027961 · Cited by 66
Providing $10^{-16}$ Short-Term Stability of a 1.5-$\mu\hbox{m}$ Laser to Optical Clocks
Hagemann, C., Grebing, C., Keßler, T., Falke, S., Lemke, N., Lisdat, C., Schnatz, H., Riehle, F., & Sterr, U. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2242597 · Cited by 59
Self-citationAdapting a Cryogenic Sapphire Oscillator for Very Long Baseline Interferometry
Doeleman, S. S., Mai, T., Rogers, A. E. E., et al. (2011) · Publications of the Astronomical Society of the Pacific · doi:10.1086/660156 · Cited by 42
Nonlinear spectroscopy of Sr atoms in an optical cavity for laser stabilization
Christensen, B. T. R., Henriksen, M. R., Schäffer, S. A., Westergaard, P. G., Tieri, D., Ye, J., Holland, M., & Thomsen, J. W. (2015) · Physical Review A · doi:10.1103/physreva.92.053820 · Cited by 35
Self-citationA second generation of low thermal noise cryogenic silicon resonators
Matei, D. G., Legero, T., Grebing, C., Häfner, S., Lisdat, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Riehle, F., et al. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012031 · Cited by 32
Self-citation
Research works printed but not linked: 11
- 10.1117/12.2228825 · doi:10.1117/12.2228825
- 10.1063/1.3290631 · doi:10.1063/1.3290631
- 10.1103/PhysRevB.92.174113 · doi:10.1103/physrevb.92.174113
- 10.1116/1.579036 · doi:10.1116/1.579036
- G. Kramer, 2004, Proceedings of the 18th European Frequency and Time Forum, Guildford, UK
- J. E. Gray, 1974, Proceedings of the 28th Annual Symposium on Frequency Control, 29-31 May 1974, Atlantic City, New Jersey, New Jersey
- 10.1364/JOSA.72.001258 · doi:10.1364/josa.72.001258
- 10.1109/PROC.1972.8696 · doi:10.1109/proc.1972.8696
- 10.1109/TIM.1981.6312409 · doi:10.1109/tim.1981.6312409
- D. W. Allan, 1981, Proceedings of the 35th Ann. Freq. Control Symposium
- J. L. Hall, 1992, Laser Manipulation of Atoms and Ions, Proceedings Internat. School of Physics Enrico Fermi, Vol. Course CXVIII
Cited by
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Atomic superheterodyne receiver based on microwave-dressed Rydberg spectroscopy
Jing, M., Hu, Y., Ma, J., Zhang, H., Zhang, L., Xiao, L., & Jia, S. (2020) · Nature Physics · doi:10.1038/s41567-020-0918-5 · Cited by 576
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Pan, S., & Zhang, Y. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2020.2993166 · Cited by 495
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citation
Metadata
- Authors
- Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., & Sterr, U.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2017-06-28
- Volume
- 118
- Issue
- 26
- Pages
- 263202-263202
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2963808380
- Cited by
- 584
- References
- 46
- FWCI
- 26.84
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- Funders
- National Institute of Standards and Technology
- Horizon 2020 Framework Programme (15SIB03 OC18)
- Alexander von Humboldt-Stiftung
- U.S. Department of Defense
- Centre for Quantum Engineering and Space-Time Research (QUEST)
- Physikalisch-Technische Bundesanstalt (PTB)
- JILA Physics Frontier Center (NSF)
- EURAMET
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.