The DOI matches its Crossref record.
Direct Optical Resolution of the Recoil Effect Using Saturated Absorption Spectroscopy
Abstract
The recoil-induced spectral doubling of the C${\mathrm{H}}_{4}$ saturated absorption peaks at 3.39 \ensuremath{\mu}m has been clearly resolved. A working resolving power of 8 \ifmmode\times\else\texttimes\fi{} ${10}^{10}$ (1 kHz half width at half-maximum), achieved with aberration-compensated parabolic optics of 32 cm diam, was available to study the height ratio and splitting of the recoil peaks. The resolved Dopplergenerated level crossings are not recoil doubled and give improved hfs information. We derive new, exact equations relating the atomic natural frequency to laboratory resonance frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Cold and ultracold molecules: science, technology and applications
Carr, L. D., DeMille, D., Krems, R. V., & Ye, J. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/5/055049 · Cited by 1,330
CODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
CODATA recommended values of the fundamental physical constants: 2002
Mohr, P. J., & Taylor, B. N. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.1 · Cited by 654
The semiclassical theory of laser cooling
Stenholm, S. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.699 · Cited by 616
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Self-citationLaser cooling and trapping of neutral atoms
Adams, C. S., & Riis, E. (1997) · Progress in Quantum Electronics · doi:10.1016/s0079-6727(96)00006-7 · Cited by 557
Atomic interferometry with internal state labelling
Bordé, C. J. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90537-9 · Cited by 535
Self-citationAdams, C. S., Sigel, M., & Mlynek, J. (1994) · Physics Reports · doi:10.1016/0370-1573(94)90066-3 · Cited by 523
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Standards of Time and Frequency at the Outset of the 21st Century
Diddams, S. A., Bergquist, J. C., Jefferts, S. R., & Oates, C. W. (2004) · Science · doi:10.1126/science.1102330 · Cited by 275
A Preliminary Measurement of the Fine Structure Constant Based on Atom Interferometry
Wicht, A., Hensley, J. M., Sarajlic, E., & Chu, S. (2002) · Physica Scripta · doi:10.1238/physica.topical.102a00082 · Cited by 260
Precision measurement of the photon recoil of an atom using atomic interferometry
Weiss, D. S., Young, B. C., & Chu, S. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.2706 · Cited by 257
Base units of the SI, fundamental constants and modern quantum physics
Bordé, C. J. (2005) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2005.1635 · Cited by 124
Self-citation
Metadata
- Authors
- Hall, J. L., Bordé, C. J., & Uehara, K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1976-11-15
- Volume
- 37
- Issue
- 20
- Pages
- 1339-1342
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2007613118
- Cited by
- 212
- References
- 0
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.