Calculations of Multiple-Harmonic Conversion of 1064-nm Radiation in Xe
Abstract
The relative strengths of harmonic intensities, generated in xenon by a strong infrared laser, are calculated from the time-dependent dynamics of the electronic charge density. The (nonperturbative) solution of the time-dependent Schr\"odinger equation for a single-electron model of the atomic system is found to predict line strengths in reasonable agreement with the observed intensities. A single time-dependent calculation provides the intensity predictions for all orders for a given laser wavelength and intensity.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The basic mechanism for HHG from single atoms is a coherent version of the Roentgen x-ray tube, through a 're-collision' process where the strong electric field of a laser pulls an electron away from an atom, then slams it back into that ionized atom.
“The basic mechanism for HHG from single atoms was outlined in numerical [119] and then analytic [120] forms as essentially a coherent version of the Roentgen x-ray tube, through a 're-collision' process where the strong electric field of a laser pulls an electron away from an atom, then slams it back into that ionized atom.”
From Roadmap of ultrafast x-ray atomic and molecular physics (2018) · cites this paper as [119]
Cites
Studies of multiphoton production of vacuum-ultraviolet radiation in the rare gases
McPherson, A., Gibson, G., Jara, H., Johann, U., Luk, T. S., McIntyre, I. A., Boyer, K., & Rhodes, C. K. (1987) · Journal of the Optical Society of America B · doi:10.1364/josab.4.000595 · Cited by 1,773 · see citing works
Multiple-harmonic conversion of 1064 nm radiation in rare gases
Ferray, M., L'Huillier, A., Li, X. F., Lompre, L. A., Mainfray, G., & Manus, C. (1988) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/21/3/001 · Cited by 1,720 · see citing works
Effects of focusing on third-order nonlinear processes in isotropic media
Bjorklund, G. C. (1975) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1975.1068619 · Cited by 492 · see citing works
Optical Third Harmonic Generation in Gases by a Focused Laser Beam
Ward, J. F., & New, G. H. C. (1969) · Physical Review · doi:10.1103/physrev.185.57 · Cited by 462 · see citing works
Time-dependent Hartree-Fock theory of multiphoton ionization: Helium
Kulander, K. C. (1987) · Physical Review A · doi:10.1103/physreva.36.2726 · Cited by 376 · see citing works
Self-citationNonlinear Optical Parametric Processes in Liquids and Gases
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-585980-6.x5001-2 · Cited by 349 · see citing works
Multiphoton ionization of hydrogen: A time-dependent theory
Kulander, K. C. (1987) · Physical Review A · doi:10.1103/physreva.35.445 · Cited by 280 · see citing works
Self-citationChu, S., & Cooper, J. (1985) · Physical Review A · doi:10.1103/physreva.32.2769 · Cited by 197 · see citing works
Time-dependent theory of multiphoton ionization of xenon
Kulander, K. C. (1988) · Physical Review A · doi:10.1103/physreva.38.778 · Cited by 170 · see citing works
Self-citationEnhancement of high optical harmonics by excess-photon ionisation
Shore, B. W., & Knight, P. L. (1987) · Journal of Physics B Atomic and Molecular Physics · doi:10.1088/0022-3700/20/2/021 · Cited by 89 · see citing works
Self-citationMultiphoton ionisation of hydrogen. A non-perturbative calculation of strong-field effects
Crance, M. (1988) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/21/15/015 · Cited by 25 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Enhanced High-Harmonic Generation Using 25 fs Laser Pulses
Zhou, J., Peatross, J., Murnane, M. M., Kapteyn, H. C., & Christov, I. P. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.752 · Cited by 353 · see citing works
Roadmap of ultrafast x-ray atomic and molecular physics
Young, L., Ueda, K., Gühr, M., Bucksbaum, P. H., Simon, M., Mukamel, S., Rohringer, N., Prince, K. C., Masciovecchio, C., Meyer, M., et al. (2018) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/aa9735 · Cited by 337 · see citing works
- Authors
- Kulander, K. C., & Shore, B. W.
- Affiliations
- Lawrence Livermore National Laboratory (US)
- ORCID
- Shore, B. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1989-01-30
- Volume
- 62
- Issue
- 5
- Pages
- 524-526
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2039463501
- Cited by
- 200
- References
- 11
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 3 · 2013: 3 · 2012: 1
- FWCI
- 14.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physical Review Letters (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Laser-Plasma Interactions and Diagnostics
- Keywords
- xenon, 1064 nm laser, time-dependent Schrödinger equation, non-perturbative dynamics, electronic charge density, single-electron model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review