Cited by 353Laser-Matter Interactions and ApplicationsAdvanced X-ray Imaging TechniquesAtomic and Molecular Physics

Enhanced High-Harmonic Generation Using 25 fs Laser Pulses

Zhou, J., Peatross, J., Murnane, M. M., Kapteyn, H. C., Christov, I. P.·1996·Physical Review Letters

Abstract

We present experimental and theoretical results on high-harmonic generation in noble gases using an 805 nm, 25 fs, titanium-doped sapphire laser. The harmonic energies observed are unexpectedly high when compared with experimental and theoretical results to date for longer excitation pulses. We observe that the efficiency of harmonic production is highest for shorter pulses. Furthermore, the wavelength of the harmonics can be tuned by adjusting the sign of the chirp of the excitation pulse, demonstrating a tunable, ultrashort-pulse, $<25\mathrm{fs}$ soft-x-ray source.

Integrity signals

Registry

Crossref · 10.1103/physrevlett.76.752

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The key enabler for both practical application and conceptual understanding of HHG has been the ability to make intense few-cycle optical pulses, enabled first by Ti:sapphire laser technology [127].

    “The key enabler for both practical application and conceptual understanding has been the ability to make intense few-cycle optical pulses, enabled first by Ti:sapphire laser technology [127].”

    From Roadmap of ultrafast x-ray atomic and molecular physics (2018) · cites this paper as [127]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhou, J., Peatross, J., Murnane, M. M., Kapteyn, H. C., & Christov, I. P.
Affiliations
University of Michigan (US)
Venue
Physical Review Letters
Published
1996-01-29
Volume
76
Issue
5
Pages
752-755
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2032543077
Cited by
353
References
15
Citations by year
2025: 3 · 2024: 8 · 2023: 7 · 2022: 11 · 2021: 11 · 2020: 4 · 2019: 7 · 2018: 6 · 2017: 6 · 2016: 13 · 2015: 11 · 2014: 6 · 2013: 11 · 2012: 13
FWCI
23.52
Type
journal article
Language
en
Open access
closed
Locations
  • Physical Review Letters (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
Keywords
high harmonic generation, noble gases, ultrashort pulses, harmonic energy, pulse chirp, soft X-ray sources, titanium-doped sapphire laser

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review