The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Single pentacene molecules detected by fluorescence excitation in a p-terphenyl crystal
Abstract
Experiments clearly prove that narrow peaks in the fluorescence-excitation spectrum of a pentacene-doped p-terphenyl crystal stem from single molecules. This claim is supported by the distribution, width, and height of the peaks, as well as by the correlation of the emitted light and the sudden drops and surges of the emission of certain peaks. We attribute these to the hole burning of a single molecule. These results show the feasibility of the optical study of a single molecule and its local environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photon Antibunching in Resonance Fluorescence
Kimble, H. J., Dagenais, M., & Mandel, L. (1977) · Physical Review Letters · doi:10.1103/physrevlett.39.691 · Cited by 1,750
Optical detection and spectroscopy of single molecules in a solid
Moerner, W. E., & Kador, L. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.2535 · Cited by 1,271
Observation of Quantum Jumps in a Single Atom
Bergquist, J. C., Hulet, R. G., Itano, W. M., & Wineland, D. J. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.1699 · Cited by 716
de Vries, H., & Wiersma, D. A. (1979) · The Journal of Chemical Physics · doi:10.1063/1.437411 · Cited by 110
Patterson, F. G., Lee, H. W. H., Wilson, W. L., & Fayer, M. D. (1984) · Chemical Physics · doi:10.1016/0301-0104(84)80005-1 · Cited by 95
Kador, L., Horne, D. E., & Moerner, W. E. (1990) · The Journal of Physical Chemistry · doi:10.1021/j100367a011 · Cited by 86
Statistical Fine Structure of Inhomogeneously Broadened Absorption Lines
Moerner, W. E., & Carter, T. P. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.2705 · Cited by 73
Carter, T. P., Manavi, M., & Moerner, W. E. (1988) · The Journal of Chemical Physics · doi:10.1063/1.455123 · Cited by 35
Cited by
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
The Larger Acenes: Versatile Organic Semiconductors
Anthony, J. E. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200604045 · Cited by 2,100
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Stable Solid-State Source of Single Photons
Kurtsiefer, C., Mayer, S., Zarda, P., & Weinfurter, H. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.290 · Cited by 1,476
On/off blinking and switching behaviour of single molecules of green fluorescent protein
Dickson, R. M., Cubitt, A. B., Tsien, R. Y., & Moerner, W. E. (1997) · Nature · doi:10.1038/41048 · Cited by 1,342
Metadata
- Authors
- Orrit, M., & Bernard, J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1990-11-19
- Volume
- 65
- Issue
- 21
- Pages
- 2716-2719
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W1998001177
- Cited by
- 1,042
- References
- 8
- FWCI
- 22.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.