Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 626

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Young’s double-slit experiment with atoms: A simple atom interferometer

Carnal, O., Mlynek, J.·1991·Physical Review Letters

Abstract

An atomic interferometer based on a Young's-type double-slit arrangement has been demonstrated. A supersonic beam of metastable helium atoms passes through a 2-\ensuremath{\mu}m-wide slit in a thin gold foil. This transversely coherent beam impinges on a second microfabricated transmission structure, consisting of two 1-\ensuremath{\mu}m-wide slits at a lateral distance of 8 \ensuremath{\mu}m. This double slit defines two possible paths on which the atoms can reach the detector slit. The good visibility of the observed fringes should make it possible to measure differential phase shifts in the interferometer of 1/3 rad in less than 10 min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.66.2689

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 626

Metadata

Authors
Carnal, O., & Mlynek, J.
Venue
Physical Review Letters
Published
1991-05-27
Volume
66
Issue
21
Pages
2689-2692
ISSN
0031-9007 (ISSN-L)
OpenAlex
W1983175027
Cited by
626
References
6
FWCI
20.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Young’s double-slit experiment with atoms: A simple atom interferometer. https://app.cochat.ai/papers/10.1103/physrevlett.66.2689
The paper
Carnal, O., & Mlynek, J. (1991). Young’s double-slit experiment with atoms: A simple atom interferometer. Physical Review Letters. https://doi.org/10.1103/physrevlett.66.2689

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.